Amplifier Communication and Protocol, XTRT, Touchscreen TWTA
Time and Date
Command Byte: '%'
Function: Sets the Amplifier internal clock. The clock is referenced when time stamping events as they are
recorded.
Parameter: "YYYY/MM/DD, hh:mm"
Example: 2002/02/08, 13:01
YYYY = 2002
MM = 02
DD = 08
hh = 13
mm = 01
Note: The hours are in 24 hour format.
Reset Processor
Command Byte: '~'
Function: Resets the processor.
Heater Standby
Command Byte: ':'
Function: Enables/Disables Heater Standby mode.
Parameters:
'0' - Disable Heater Standby.
'1' - Enable Heater Standby.
Note: The "XTRT Series Amplifiers" power up with heater standby enabled.