Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Remove the toe panel (See page 4-61).
3. Remove the drip cover by lifting it off the
CCU. There are metal tabs on the bracket
that fit into slots at front and back of cover.
Tab Slots
4. Use a small flat blade screwdriver to lift the
locking tab securing CCU to the washer.
5. Slide the CCU towards the front of the
6. Release two clips securing the side access
7. It is advisable to take a picture of the wire
8. Disconnect the wires from the CCU by
9. There are colored marks on the rast
10. Continue disconnecting until all Rast
11. Disconnect three more wire connectors on
12. Slide the CCU forward to release the tabs
Locking Tab
4-62
washer to release tabs from keyhole slots in
the bracket, in the base of the washer, and
remove it.
cover and open the cover to gain access to
the wire connectors.
Two Access
Cover Clips
connectors, before disconnecting them, for
proper reinstallation.
pressing the locking tab down and pulling
the Rast connector out.
connectors that correspond to the colors
on the CCU for each connector. Rast
connectors are also keyed to help in proper
reinstallation.
connectors have been removed from the
CCU.
the top of the CCU by pressing the locking
tab and pulling the connector out.
from the mounting bracket. Remove the
CCU.