Tub And Spin Basket Assembly - Maytag MLE22PD Service Manual

Commercial stack washer/dryer 50hz
Table of Contents

Advertisement

TuB anD Spin BaSKeT aSSeMBlY

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the chemical dispenser assembly
(See page 4-55).
4. Remove the washer front support bracket
(See page 4-60).
5. Remove the bellow (See page 4-76).
6. Disconnect the tub to pump hose from
pump (See page 4-78).
7. Remove the back panel (See page 4-68).
8. Disconnect the vent tube (See page 4-73).
9. Remove the wiring connector from the
temperature sensor (See page 4-71).
10. Remove the motor (See page 4-72).
11. Disconnect the pressure sensor hose from
the bottom of the pressure sensor. Twist and
pull the hose off the switch.
12. Place container below pump filter opening
to catch any water that is left in washer.
13. Unscrew pump filter, pull it out of pump.
Let any water drain, then reinstall the filter.
14. Disconnect the drain hose from the back
of the pump filter. Move the clamp down the
hose. Pull the drain hose off the back of the
pump filter.
4-78