Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Pins A & B
See page 4-53 for the procedure for accessing
the RFI line filter.
To check the RFI line filter at the component
terminals, perform the following steps.
1. Unplug washer or disconnect power.
2. Disconnect the wire connectors from the
RFI line filter.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to the
following connector pins (shown above).
The meter should indicate 0Ω for each
measurement.
Pins A and B
Pins C and D
Electrical Shock Hazard
rFi line FilTer
Pins C & D
5-3
To check the RFI line filter at the CCU,
perform the following steps.
1. Unplug washer or disconnect power.
2. Disconnect the RFI line filter connector IF2
(See page 4-63) from the CCU.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to wire
harness connector pins 1 and 2. The meter
should indicated 30Ω.
Connector IF2 at CCU