Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Drive Motor
Connector
See page 4-34 for the procedure for accessing
the dryer drive motor.
1. Unplug dryer of disconnect power.
2. Disconnect the connector from the drive
motor.
3. Set the ohmmeter to the R X 1 scale.
4. Touch ohmmeter test leads to the contact
points shown in the table below.
Winding Resistance
Main
2.4 - 3.6Ω
Start
2.4 - 3.8Ω
Drive MOTOr - DrYer
Contact Point
Lt. blue wire in back
at pin 4 & bare copper
wire on pin 5 of black
drive motor switch
Lt. blue wire in back
at pin 4 & bare copper
wire on pin 3 of black
drive motor switch.
Electrical Shock Hazard
Bare Motor Wire
Motor
Thermal
Overload
Blue Wire
To Belt
Switch
MOTOR CONNECTIONS
Lt. Blue
Black-White
Red
Pluggable Drive Motor Switch
5-7
Motor Connector
Pin 1
(Red)
Pin 5
(White-Orange)
Pin 3
(Violet)
Pin 4
(Blue) To
Belt Switch
Pin 6
(Black - White)
Pin 2
(Red)
Blue-White (Elec)
White (Gas)
Green-Yellow
Contacts
Red