Figure 2 Performance Characteristics Of Xds35I; Figure 3 Performance Characteristics Of Xds35Ie - Edwards XDS35iR Instruction Manual

Scroll pumps
Table of Contents

Advertisement

Table 3 Performance characteristics
Gas ballast control
position
0
1
2

Figure 2 Performance characteristics of XDS35i

Note:
XDS35i can operate with high peak power for 90 seconds before activation of a thermal
protection algorithm which reduces rotational and pumping speed.

Figure 3 Performance characteristics of XDS35iE

The power consumption of the enhanced version at high inlet pressure can be lowered
by a further 100 W more with the installation of a second exhaust silencer by an
NW25 T‑piece.
A73001880_P
A73001880_P - Technical data
XDS35i Ultimate to-
tal pressure (mbar)
< 0.01
< 0.02
< 10.0
Page 14
XDS35iE Ultimate
total pressure
(mbar)
< 0.03
< 0.04
< 10.0
05/2022 - ©Edwards Limited
Gas ballast flow
-1
(l min
)
-
3
12