4
Fully extend the rebound damper shaft. Push the syringe plunger
Fully extend the rebound damper shaft. Push the syringe plunger
down, then release the plunger. Allow the bladder to expand and
down, then release the plunger. Allow the bladder to expand and
retract until it stops in a resting position.
retract until it stops in a resting position.
5
Unthread the syringe bleed fitting from the bleed port.
Unthread the syringe bleed fitting from the bleed port.
Oil may eject from the bleed port if the bladder is not in a resting
position. Wear safety glasses.
6
Install the bleed screw and tighten it.
Install the bleed screw and tighten it.
Wipe away any excess oil.
Wipe away any excess oil.
⚠ CAUTIO N
T10
1.7 N∙m (15 in-lb)
52