Dc-Side Components; Dc Connector Panel; Dc Disconnectors - Delta M50A-260 Installation And Operation Manual

Solar inverter
Table of Contents

Advertisement

4.6

DC-side components

Related topics
"5.5 Planning the connection of the solar modules (DC)", page
41
"7.9 Connecting the solar modules (DC)", page 80

4.6.1 DC connector panel

Fig. 4.6:
DC connection panel
The DC connector panel has 12 pairs of DC connectors (6 MPP
trackers with 2 pairs of DC connectors each).
Plug type:
DC+: Amphenol H4 for 4/6 mm
H4CFC4D●MS)
DC–: Amphenol H4 for 4/6 mm
H4CMC4D●MS)
12 pairs of DC plugs are supplied in the scope of delivery.
Fig. 4.7:
Label showing the assignment of each DC connector
The assignment of the individual DC connectors to the module
strings is shown on a label.
Installation and Operation Manual M50A_260 RPI503M260000 Product version L and M EU V1.3 EN 2023-08-14
2
(Amphenol part number
2
(Amphenol part number

4.6.2 DC disconnectors

Fig. 4.8:
DC disconnectors
The DC disconnectors are marked on the inverter with the words
SWITCH 1 and SWITCH 2.
DC disconnector 1 separates the DC strings of MPP trackers 1
to 3.
DC disconnector 2 separates the DC strings of MPP trackers 4
to 6.
Germany: The DC disconnectors meet the requirements of
VDE0100-712.
France: The DC disconnectors meet the requirements of
UTE 15-712-1.
Fig. 4.9:
Both DC disconnectors in the OFF position = the
connection to the solar modules is disconnected
The connection between the inverter and the solar modules is
disconnected when both DC disconnectors are in the OFF posi-
tion.
4 Product overview
DC-side components
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rpi503m260000