5.7
Planning the device communication
and plant monitoring
Related topics
"6. Planning the Commissioning", page 51
"7.7 Connecting the communication card", page 63
5.7.1 Introduction
The inverter offers the following options for communication with
other devices (e.g. PC, smartphone, data logger):
●
RS485 (communication card with RS485 connections,
digital inputs, dry contacts, external power-off and 12 V
power supply)
●
Sub-1G antenna (included in scope of delivery)
●
Wi-Fi module (optional accessory)
Installation and Operation Manual M50A_260 RPI503M260000 Product version L and M EU V1.3 EN 2023-08-14
Planning the device communication and plant monitoring
5.7.2 Components of the communication card
The connections for RS485, the digital inputs, the
dry contacts and the external power-off (EPO) are
all on the communication card. This means that
the installation work can be combined.
DC
6
Fig. 5.27:
Components of the communication card
1 Digital inputs and external power-off (terminal block)
2 Power supply for internal fan 1
3 DIP switch for the RS485 termination resistor
4 2 x dry contacts (terminal block)
5 RS485 (terminal block)
6 Protection against electromagnetic interference (EMI)
Connection
2x RS485 (DATA+ and DATA–)
1x VCC (12 V, 0.5 A)
6x digital inputs
2x dry contacts
1x external power-off (EPO)
Table 5.4.: Connections on the communication card
5 Planning the installation
1
5
4
Connection type
Terminal block
Terminal block
Terminal block
Terminal block
Terminal block
2
3
45