Dc-Side Components; Dc Connector Panel - Delta M70A-260 Installation And Operation Manual

Solar inverter
Hide thumbs Also See for M70A-260:
Table of Contents

Advertisement

4.6

DC-side components

Related topics
"5.5 Planning the connection of the solar modules (DC)", page
43
"7.8 Connecting the solar modules (DC)", page 82

4.6.1 DC connector panel

The DC connector panel has 18 pairs of DC connectors (6 MPP
trackers with 3 pairs of DC connectors each).
Plug type:
DC+: Amphenol H4 for 4/6 mm
H4CFC4D●MS)
DC–: Amphenol H4 for 4/6 mm
H4CMC4D●MS)
18 pairs of DC plugs are supplied in the scope of delivery.
Fig. 4.6:
DC cover plate on the DC connection panel
Fig. 4.7:
DC connection panel without DC cover plate
The DC cover plate protects the DC connectors behind it from
environmental influences The DC cover plate can be unscrewed
to connect DC cables.
Installation and operation manual M70A_260 Flex RPI703M26000 EU V1.1 EN 2022-08-02
2
(Amphenol part number
2
(Amphenol part number
Fig. 4.8:
Label showing the assignment of each DC connector
The assignment of the individual DC connectors to the module
strings is shown on a label.