5.7.6 Connection of a DC1 data collector from
Delta
You can use the DC1 data collector for, among other things:
Commissioning the inverter (see "6. Planning the Commis-
sioning", page 51 and "8. Commissioning", page 84)
Updating the firmware
Connecting to the MyDeltaSolar Cloud or another monitor-
ing system
The inverter can be connected to the DC1 via RS485, Sub-1G or
Wi-Fi.
Connection via RS485
Observe the general instructions in section "5.7.5 Connection of
a data logger via RS485", page 46.
The DC1 does not have an integrated RS485 termination resis-
tor. For this reason, refer to the information in Fig. 5.28.
3
120Ω
4
Termination resistor = ON
Fig. 5.28:
RS485 connection diagram for a DC1 data collector
with multiple inverters
Installation and Operation Manual M50A_260 RPI503M260000 Product version L and M EU V1.3 EN 2023-08-14
Termination resistor = OFF
3
4
5 Planning the installation
Planning the device communication and plant monitoring
Termination resistor = OFF
Termination resistor = OFF
Termination resistor = ON
Termination resistor = ON
47