Figure 6-8 Station-To-Station Connection Test (Origination) Via Fccs - NEC NEAX 2400 IMX Manual

Fusion network system
Hide thumbs Also See for NEAX 2400 IMX:
Table of Contents

Advertisement

STEP 4: The call terminates on STN B.
STEP 5: Confirm the speech condition is sufficient (no noise, not one-way speech, etc.).
STEP 6: Replace the handset of STN A.
STEP 7: Repeat the above steps for all Fusion links.
3.1.2
FCCS Call Termination Test
STEP 1: Using the MBCT command, make busy all trunks in the origination route except the trunk to be tested
at Node B.
STEP 2: Lift the handset of STN B in Node B.
STEP 3: Dial a Telephone Number (STN A) which belongs to the self-node.
STEP 4: The call terminates on STN A.
STEP 5: Confirm the speech condition is sufficient (no noise, not one-way speech, etc.).
STEP 6: Replace the handset of STN B.
STEP 7: Repeat the above steps for all Fusion links
.
Dial TELN
"420000"
LC
STN A
TELN: 410000
STN: 2000
Call Origination
Note:
Using the MBCT command, make busy all B-channels in the route except the trunk to be tested.

Figure 6-8 Station-to-Station Connection Test (origination) via FCCS

Node A (Self-Node)
FCCS
B ch: busy
B ch: idle
B ch: busy
B ch: busy
ND-70185 (E)
Get other manuals https://www.bkmanuals.com
POST INSTALLATION TEST
FCCS Network Connection Test
Node B
LC
STN B
TELN: 420000
STN: 2000
RG
MBCT Comman
d
(Make Busy Information)
0: Make idle
1: Make Busy
Check
CHAPTER 6
Page 139
Revision 3.0

Advertisement

Table of Contents
loading

Table of Contents