3.3 Centralized Management Report-Fusion
To collect fault information in a Fusion network, the Centralized Management Report-Fusion is used. This
feature provides automatic reporting of fault occurrence from Local Nodes to Center Node. Service condi-
tions for this feature are shown below.
13-H
1. xxxx xxxx 0010 1222
4. x0010 1110 10110 1FFF
7. E23C CAAB12 000 0000
NEC
Centralized MAT
Fusion

Figure 3-13 Centralized Management Report-Fusion

Center Node for Centralized Management Report-Fusion is specified in the following system data:
ASYDL, SYS1, Index 532 (FPC of Center Node for Centralized Management Report-Fusion).
At Center Node, system messages received from the other nodes are stored in the buffer memory for
Centralized Management Report-Fusion.
The MAT connected to Center Node polls only the self-node.
Office Name (ASYD, Index 96 through 115) is used for identification of each node.
When a system message printer is connected to a node other than Center Node, system messages sent
to Center Node are also output to the system message printer.
When a system message has been sent to Center Node, the message is regarded as an old message.
When the system fails transmission of a system message to Center Node, retry operation is executed.
When the retry operation also fails, transmission is aborted and the message is to be sent together with
the next system message.
FCCS
Node D
ND-70185 (E)
Get other manuals https://www.bkmanuals.com
SYSTEM CONFIGURATION
FCCS
Node A
FCCS
System Considerations
Node B
Fault!
FCCS
Node C
CHAPTER 3
Page 21
Revision 3.0