Figure 7-21 23-U Fcch Status Notification - Spanning Tree Generation End - NEC NEAX 2400 IMX Manual

Fusion network system
Hide thumbs Also See for NEAX 2400 IMX:
Table of Contents

Advertisement

9.4 FLTINF = 1EH Spanning Tree Generation End
This message is displayed when Spanning Tree Generation is complete. The detailed information is indicated
in the following format.
"Spanning Tree Generation End"
1. xx 0x 1E xx xx xx xx xx
4. xx xx xx xx xx xx xx xx
b7
b7
0
0
TRC RS
b7
MG
U
FCH Mounting Location

Figure 7-21 23-U FCCH Status Notification - Spanning Tree Generation End

2. xx xx
xx xx xx xx xx xx
5. xx xx xx 00 0000 0000
b7
b0
:
:
:
:
b7
b0
Spanning Tree Configuration Results
b0
1E
b0
FCH CKT No.
b0
MG: Module Group
G
U: Unit (0-3)
G: Group (0-23)
ND-70185 (E)
Get other manuals https://www.bkmanuals.com
23-U FCH Status Information
3. xx xx xx xx xx xx
6. 00 00 00 00 00 00
b7
7
6
5
4
15
14
13
12
23
22
21
20
..............
239 238 237 236
247
246 245 244
255
254 253 252
* Each bit represents FPC (Fusion Point Code). When "1" is set,
the FPC has joined the spanning tree configuration.
32 Bytes
FLTINF: 1EH = Spanning Tree Generation
End Notification
TRC: Trace Confirmation Bit
(0/1 = Status Notification / Primitive Trace)
RS: Receive / Send Primitive Trace (not effective)
FCH CKT No. = Circuit No. of FCH
TROUBLESHOOTING
xx xx
00 00
b0
3
2
1
-
11
10
9
8
19
18
17
16
........
235
234 233
232
243
242 241
240
251
250 249
248
CHAPTER 7