2.3 Test Procedure
STEP 1: Set the MODE switch to 9 (Fusion Link Test) from 8 (standard setting) on the FCH card and initialize
the circuit card by turning the MB switch ON→OFF
(1) Change the mode switch (8
FCH card
Mode:
8 9
screw driver
8
Front View
Note:
Be sure to initialize the FCH (PA-FCHA) card after changing the setting of the Mode Switch.
STEP 2: Select an appropriate loopback point by setting the switch (SW01/SW13B).
Select a loopback point by setting the switch.
DTI (PA-24DTR)
OPE
N-OPE
SW00
PCM
FRM
BER
RMT
AIS
SW01
BL23
1
2
3
4
5
6
7
8
OFF
1
2
3
4
5
6
7
8
OFF
1
2
3
4
5
6
7
8
OFF
STEP 3: When the LYR LED flashes at 60-INT, the loopback in the block specified in Step 2 is OK.
9).
(2) Initialize the FCH card.
Mode Switch
8: standard setting
9: Fusion Link Test Mode

Figure 6-5 How to Set the Fusion Link Test Mode

To set "Internal Loopback"
DTI
SW01/SW13B
MB
Payload
Line (External)
Internal

Figure 6-6 Loopback Point Designation

ND-70185 (E)
Get other manuals https://www.bkmanuals.com
POST INSTALLATION TEST
Repair Procedure When LED Indicates Abnormality
DTI
FCH
PA-
PA-
FCHA
24DTR
MB
(i) UP
(ii) DOWN
Anti-static Kit
Front View
4
3
2
1
ON
Anti-static Kit
Setting a Loopback point......
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
CHAPTER 6
Page 137
Revision 3.0