Commissioning
4.2

Rack installation

Extreme environmental conditions
Extreme environmental conditions can cause damage to the device.
• Avoid extreme environmental conditions.
• Protect the device against dust, moisture and heat.
• Do not block the ventilation slots of the device.
Incorrect installation
Mounting the device in a way that deviates from the documentation can impair its functionality.
• Mount the device only in the orientations shown in the documents.
The industrial PC is designed for installation in 19-inch racks in machine and plant engineering. The
environmental conditions specified for operation must be observed (see chapter 9 Technical data [} 50]).
Dimensions
The dimensions of the industrial PC are used to prepare the rack and to mount the device correctly in the
rack.
All dimensions are in mm.
481,7
8,35
465
Frontansicht
Fig. 17: Device dimensions
Beckhoff provides the following ordering option C9900-M712 with telescopic rails and brackets:
• C9900-M712: Drawer slides for C5210 and C5240. Telescopic rails and bracket set for installation in
19-inch racks
The telescopic rails and brackets allow you to pull the industrial PC out of the rack. This makes it easier to
open or connect the industrial PC, for example.
Instructions for mounting the C9900-M712 ordering option are provided in the following document:
https://download.beckhoff.com/download/technical_drawings/Industrial_PC/Control_cabinet_Industrial_PCs/
C52xx/C5240_C9900-M712.pdf