  • Page 1 Installation and Operating instructions for Economy built-in Panel PC CP62xx Version: 2.7 Date: 2012-04-02...
  • Page 2: Table Of Contents

    Installation of the PC in the control cabinet Installation in a control cabinet wall Earthing measures Mounting of the Panel-PC Power Supply Connection Beckhoff power supply technology Pin assignment of the connector Fitting the cable Material for assembling the connectors Assembling the connectors...
  • Page 3 Shutting down Disposal UPS Software Components (optional) Installation on the PC Help files Troubleshooting Fault correction Beckhoff Support & Service Beckhoff branches and partner companies Beckhoff Headquarters Beckhoff Support Beckhoff Service Appendix Assembly dimensions Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference...
  • Page 4: Foreword

    Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH. Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH apply.
  • Page 5: Description Of Safety Symbols

    Foreword Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. Acute risk of injury!! If you do not adhere the safety advise adjoining this symbol, there is DANGER immediate danger to life and health of individuals! Risk of injury!
  • Page 6: Basic Safety Measures

    Foreword Basic safety measures Only switch the PC off after Before the Industrial PC is switched off, software that is running must closing the software be properly closed. Otherwise it is possible that data on the storage medium is lost. Please read the section Switching the Industrial PC on and off.
  • Page 7: Operator's Obligation To Exercise Diligence

    The operator must initiate such inspections in good time. Do not open the housing of the build-in Panel PC For technical support contact Beckhoff Service. Note Procedure in the event of a...
  • Page 8: Product Description

    Product Description Product Description Appropriate Use The CP62xx Build-in Panel PC is designed for industrial application in machine and plant engineering. A steel plate housing with aluminum front contains a TFT display, touch screen/ pad (optional) and a PC keyboard (optional).
  • Page 9: Power Supply

    Product Description Power supply X110 The power supply for the Industrial PC is established via the socket. Power Additional plug-in cards (optional) Type plate There is a type plate on the top of the Industrial PC which provides information about the hardware configuration of the Industrial PC at the time it was supplied.
  • Page 10: Installation Instructions

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. CP62xx...
  • Page 11: Installation Of The Pc In The Control Cabinet

    Installation Instructions Installation of the PC in the control cabinet The built-in Panel PC CP62xx is designed for mounting in control cabinets in machine and plant engineering applications. The ambient conditions specified for operation must be observed (see chapter Technical data).
  • Page 12: Mounting Of The Panel-Pc

    Installation Instructions Mounting of the Panel-PC Please refer to the tables for Panel-PC cutout dimensions. Mounting of the Panel-PC Clamping levers Release clamping levers, Insert the PC into the cutout. Release the clamping levers with a No. 2.5 Allen key. Folding them out Turn the clamping levers to the side through 90°...
  • Page 13: Power Supply Connection

    However, over time this reduces the service life of the battery. The new Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery, thereby reducing the load on the battery.
  • Page 14: Pin Assignment Of The Connector

    Installation Instructions In order to maintain a screen display for the Industrial PC in the event of a power failure, the power supply unit is equipped with a UPS output for connecting a Control Panel. This enables a power failure to be visualized and displayed to the user.
  • Page 15: Fitting The Cable

    Installation Instructions Fitting the cable Wiring in accordance with Fit the cables for the power supply of the Industrial PC, the connection of wiring diagram the battery pack as well as the connection of the power-switch in accordance with the wiring diagram, using the included material for assembling the connectors.
  • Page 16: Connecting Power Supply

    Installation Instructions Connecting Power Supply The external wiring consists of the connection of the power supply, the battery pack (optional) and the connection of customized components for shutting down the PC. Cable Cross Sections Note cable cross sections, For the connection of the power supply, wiring with a cable-cross-section of 1.5 mm must be used.
  • Page 17: Wiring Diagram

    Installation Instructions Wiring diagram Wiring according to the wiring diagram (the circuit of PC_ON and Power- Status is symbolical): Wiring diagram external switch and power supply Connection of the Battery Pack and UPS Output Connection of the Battery Pack and UPS Output only in combination with Note integrated UPS (order option).
  • Page 18: Connecting Devices

    Installation Instructions Connecting devices Power supply plug The power supply plug must be withdrawn! Attention Please read the documentation for the external devices prior to connecting them. During thunderstorms, plug connector must neither be inserted nor removed. When disconnecting a plug connector, always handle it at the plug. Do not pull the cable! Connecting cables The connections are located at the top of the Industrial PC and are...
  • Page 19: Operating Instructions

    Operating Instructions Operating Instructions Please also refer to chapter Foreword. Switching the Industrial PC on and off Switch on The Industrial PC does not have its own mains switch. The Industrial PC will start when the equipment is switched on, or when it is connected to the power supply.
  • Page 20: Keyboard Codes

    Operating Instructions Keyboard codes Type-dependent number of Depending on the precise type, the Control Panel can have fewer keys keys than those described here. Operation The cursor is the blinking character that marks the point at which the next character entered will be displayed. The cursor is also known as the insertion point.
  • Page 21 Operating Instructions The meaning of the function keys, F1 to F10, is determined by the software and is displayed at the bottom edge of the display. The function of the special keys above the display is also determined by Einschub Einschub Einschub Einschub...
  • Page 22: Servicing And Maintenance

    Servicing The build-in Panel PC requires no maintenance. Do not open the housing of the build-in Panel PC For technical support contact Beckhoff Service. Note Replacing the battery on the motherboard A used battery on the motherboard has to be replaced. See also chapter Access to the drives and the battery.
  • Page 23: Ups Software Components (Optional)

    The driver software comes with a detailed help function. System The help files can be called up either directly from the configuration register by clicking the Help button, or under via Start > Programs > Beckhoff > UPS software components. CP62xx...
  • Page 24: Troubleshooting

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause Call Beckhoff Service The Industrial PC does not boot Setup settings are incorrect Check the setup settings fully...
  • Page 25: Beckhoff Support & Service

    Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com You will also find further documentation for Beckhoff components there.
  • Page 26: Appendix

    Appendix Appendix Assembly dimensions Notice mounting orientation The assembly of the unit must take place with the orientation diagrammed Attention here. All dimensions are in mm, similar picture. Build-in Panel PC CP62xx with 12“, 15“, 19“ and 24“ display side view bottom view rear view Dimensions CP620x...
  • Page 27: Technical Data

    Appendix Technical data Dimensions Dimensions (W x H x D): see section Assembly dimensions. Operation in areas that are The Industrial PC must not be used where there is a risk of explosion. subject to explosion hazard The following conditions must be observed during operation: Environmental conditions Ambient temperature: 0 to 55°C...