Owner's Information; Copy Of Safety Label - Regency Fireplace Products Gi33LE Owners & Installation Manual

Gas insert
Hide thumbs Also See for Gi33LE:
Table of Contents

Advertisement

owner's information

Copy of Safety Label

A copy of the label that accompanies each Gi33LE gas insert is below.
Duplicate Serial number/Copie No de série
Gi33LE Serial Label
Listed: VENTED GAS FIREPLACE HEATER/FOYER AU GAZ À ÉVACUATION
Certified to/Certifi pour :
é
CSA 2.17-2017
ANSI Z21.88-2019
CSA 2.33-2019
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
C # 4001172
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold pressure
Orifice
Minimum input
Maximum input
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold Pressure
Orifice
Minimum Input
Maximum Input
Minimum Clearances to Combustibles
from Insert/Dégagements min. combustible
Side wall /mur latéral
A
8" (203 mm)
Ceiling/Plafond
B
60" (1524 mm)
Mantel/Manteau
C
48" (1220 mm)
Min. Alcove Width/
Largeur min. alcôve
K
56" (1422 mm)
Max. Alcove Depth/
L
36" (914 mm)
Prof. max. alcôve
FPI Fireplace Products International, Ltd
Delta BC, CANADA
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas
and Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Cet appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, conformément au National Fuel Gas
Code ANSI Z223.1, ou au CSA-B149.1 en vigueur.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
AVERTISSEMENT : Ce foyer a été converti pour être utilisé avec un foyer au gaz encastrable et ne peut être utilisé pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remises en place et que le foyer ait été homologué de nouveau par une autorité
compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
For use only with barrier (Part # 391-201/P) Follow installation instructions. Pour utilisation uniquement avec l'écran(Pièce n°391-201/P)
Electrical supply / Alimentation électrique 115VAC, Less than 1.5A, 60Hz,
CATEGORY I / CATÉGORIE I
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
CANADIAN ENERGY
PERFORMANCE
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
VERIFIED
Natural Gas / Gaz naturel
RENDEMENT
Propane Gas / Gaz propane
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
To find the safety label, remove faceplate from the front of your unit (see manual);
Part #:
920-669
the safety label is located below the glass (see picture).
Colour:
Black on grey except what is highlighted is printed red
DO NOT REMOVE THE LABEL FROM THE UNIT.
Size:
(File at 100%) 6.495"W x 8.45" H
Material:
2 ml silver matt polyester (DPM SMS)
April 12/2023:
Created draft
May 23/2023:
Updated draft
6
| Gi33 Direct Vent Gas Insert
591
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
591
Serial No. / No de série
ENCASTRABLE AU GAZ NATUREL
MODEL Gi33LE-NG
MODÈLE Gi33LE-NG
5"
WC
(1.25 kPa)
Pression d'alimentation minimale
1.1"
WC
(0.27 kPa)
Pression de sortie (manifold) - basse
3.8"
WC
(0.95 kPa)
Pression de sortie (manifold) - max.
#33
DMS
Taille de l'orifice
20,500
Btu/h
(6.01 kW)
D bit calorifique minimal
é
38,500
Btu/h
(11.28 kW)
D bit calorifique maximal
é
ENCASTRABLE AU GAZ PROPANE
MODEL Gi33LE-LP
MODÈLE Gi33LE-LP
11"
WC
(2.74 kPa)
Pression d'alimentation minimale
2.9"
WC
(0.72 kPa)
Pression de sortie (manifold) - basse
10.5"
WC
(2.61 kPa)
Pression de sortie (manifold) - max.
Taille de l'orifice
#50
DMS
D bit calorifique minimal
é
20,000
Btu/h
(5.86 kW)
D bit calorifique maximal
é
36,500
Btu/h
(10.70 kW)
Mantel Clearances / Dégagements manteau
s
Min. Hearth Depth/
Prof. min. âtre
Min. Hearth Width/
Largeur min. âtre
G
A
Max. Mantle Depth/
Prof. max. manteau G 12" (305 mm)
L
B
C
D
E
K
MADE IN CANADA /FABRIQUÉ AU CANADA
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
Suivre les consignes d'installation.
Fan Part #/Pièce ventilateur 911-071/P
64.30%
64.32%
Safety Label Location
Regency units are constantly improving. Check the safety
label on the unit and if it is different from the copy provided
here, the label on the unit is correct.
For the State of Massachusetts, installation and repair must be
done by a plumber or gas fitter licensed in the Commonwealth
of Massachusetts.
For the State of Massachusetts, flexible connectors shall not
exceed 36 inches in length.
For the State of Massachusetts, the appliance's individual manual
shutoff must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon
monoxide alarm in accordance with NFPA 720 and a CO alarm
with battery backup in the same room where the gas appliance
D 12" (305 mm)
is installed
E 36" (914 mm)
920-669
.