Owner's Information; Copy Of Safety Label - Regency Fireplace Products Gi29LE Owners & Installation Manual

Gas insert
Table of Contents

Advertisement

owner's information

Copy of Safety Label

A copy of the label that accompanies each Gi29LE gas insert is below.
Duplicate Serial number/Copie No de série
Gi29LE Serial Label
Listed: VENTED GAS FIREPLACE HEATER/FOYER AU GAZ À ÉVACUATION
Certified to/Certifi pour :
é
CSA 2.17-2017
ANSI Z21.88-2019
CSA 2.33-2019
Refer to Intertek's Directory of Building Products for detailed information.
C # 4001172
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold pressure
Factory Equipped for Altitude 0-2,000ft (0-610m)
Orifice
Minimum input
Maximum input
Field Convertible for Altitude 2,000 - 4,500ft (610m-1370m) - Use Conversion Kit #311-980
Orifice
Minimum Input
Maximum Input
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold Pressure
Orifice
Minimum Input
Maximum Input
Minimum Clearances to Combustibles
from Insert/Dégagements min. combustible
Side wall /mur latéral
A
8" (203 mm)
Ceiling/Plafond
B
60" (1524 mm)
Mantel/Manteau
C
41.5" (1055 mm)
Min. Alcove Width/
Largeur min. alcôve
K
54" (1372 mm)
Max. Alcove Depth/
L
36" (914 mm)
Prof. max. alcôve
FPI Fireplace Products International, Ltd
Delta BC, CANADA
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Cet appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, conformément au National Fuel Gas
Code ANSI Z223.1, ou au CSA-B149.1 en vigueur.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
AVERTISSEMENT : Ce foyer a été converti pour être utilisé avec un foyer au gaz encastrable et ne peut être utilisé pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remises en place et que le foyer ait été homologué de nouveau par une autorité
compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
For use only with barrier (Part # 311-417/P) Follow installation instructions. Pour utilisation uniquement avec l'écran(Pièce n°311-417/P)
Electrical supply / Alimentation électrique 115VAC, Less than 1.5A, 60Hz,
CATEGORY I / CATÉGORIE I
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel
RENDEMENT
Propane Gas / Gaz propane
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
To find the safety label, remove faceplate from the front of your unit (see manual);
Part #:
920-518
the safety label is located below the glass (see picture).
Colour:
Black on grey except what is highlighted is printed red
Size:
(File at 100%) 6.495"W x 8.66" H
DO NOT REMOVE THE LABEL FROM THE UNIT.
Material:
2 ml silver matt polyester (DPM SMS)
May 05/2022:
Created draft
6
| Gi29 Direct Vent Gas Insert
574
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
574
Serial No. / No de série
MODEL Gi29LE-NG
ENCASTRABLE AU GAZ NATUREL
MODÈLE Gi29LE-NG
Pression d'alimentation minimale
5"
WC
(1.25 kPa)
Pression de sortie (manifold) - basse
1.1"
WC
(0.27 kPa)
Pression de sortie (manifold) - max.
3.8"
WC
(0.95 kPa)
Taille de l'orifice
D bit calorifique minimal
é
#38
DMS
D bit calorifique maximal
é
17,000
Btu/h
(4.98 kW)
31,500
Btu/h
(9.22 kW)
#39
DMS
16,500
Btu/h
(4.83 kW)
30,500
Btu/h
(8.93 kW)
MODEL Gi29LE-LP
ENCASTRABLE AU GAZ PROPANE
MODÈLE Gi29LE-LP
11"
WC
(2.74 kPa)
Pression d'alimentation minimale
2.9"
WC
(0.72 kPa)
Pression de sortie (manifold) - basse
10.5"
WC
(2.61 kPa)
Pression de sortie (manifold) - max.
#52
DMS
Taille de l'orifice
17,000
Btu/h
(4.98 kW)
D bit calorifique minimal
é
31,500
Btu/h
(9.22 kW)
D bit calorifique maximal
é
Mantel Clearances / Dégagements manteau
s
Min. Hearth Depth/
Prof. min. âtre
Min. Hearth Width/
Largeur min. âtre
G
A
Max. Mantle Depth/
Prof. max. manteau G 12" (305 mm)
L
B
C
D
E
MADE IN CANADA /FABRIQUÉ AU CANADA
K
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
Suivre les consignes d'installation.
Fan Part #/Pièce ventilateur 911-071/P
63.88%
62.33%
Safety Label Location
Regency units are constantly improving. Check the safety
label on the unit and if it is different from the copy provided
here, the label on the unit is correct.
For the State of Massachusetts, installation and repair must be
done by a plumber or gas fitter licensed in the Commonwealth
of Massachusetts.
For the State of Massachusetts, flexible connectors shall not
exceed 36 inches in length.
For the State of Massachusetts, the appliance's individual manual
shutoff must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon
monoxide alarm in accordance with NFPA 720 and a CO alarm
with battery backup in the same room where the gas appliance
D 12" (305 mm)
is installed
E 36" (914 mm)
920-518
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gi29le-ngGi29le-lp

Table of Contents