owner's information

Important Message

SAVE THESE INSTRUCTIONS
The Gi33LE gas insert must be installed in
accordance with the instructions in this manual; read
them carefully before installing the unit. Consult
the authority having jurisdiction to determine the
need for permits prior to starting the installation.
It is the responsibility of the installer to ensure
this fireplace is installed in compliance with the
manufacturer's instructions and all applicable codes.

Before You Start

We are required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following.
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED SERVICE
PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A PROFESSIONAL
SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED DUE
TO LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE
THAT CONTROL COMPARTMENTS,
BURNERS, AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLIANCE
ARE KEPT CLEAN.
10
| Gi33 Direct Vent Gas Insert
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE
A SERIOUS HOUSE FIRE.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE GLASS,
AND SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
A BARRIER DESIGNED TO REDUCE
THE RISK OF BURNS FROM THE HOT
VIEWING GLASS IS PROVIDED WITH
THIS APPLIANCE AND SHALL BE
INSTALLED FOR THE PROTECTION
OF CHILDREN AND OTHER AT-RISK
INDIVIDUALS
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
IF THE BARRIER BECOMES DAMAGED,
IT MUST BE REPLACED WITH THE
MANUFACTURER'S BARRIER FOR
THIS APPLIANCE.
ANY SAFETY SCREEN, GUARD, OR
BARRIER REMOVED FOR SERVICING
AN APPLIANCE MUST BE REPLACED
P R I O R
T O
O P E R A T I N G
APPLIANCE.

For Your Safety

This appliance requires air for proper combustion.
Always provide adequate combustion and ventilation
air. Follow instructions and information in CSA
B149.1 (in Canada) or the National Fuel Gas Code
ANSI Z223.1 (in the USA), regarding requirements
for combustion and ventilation air.

Specifications

Pressures over 1/2 psig, the pipe to the unit must
be disconnected.
Gas Max. Input Capacity:
Natural Gas 38,500 Btu/h
Propane
36,500 Btu/h
Min. Input
Natural Gas 20,500 Btu/h
Propane
20,000 Btu/h
Fuels: Approved for use with natural gas and
propane. Approved as is for use at 0' to 4,500'
(0-1,370 m).
Electrical: 120 V A.C. system.
Circulation Fan: Variable speed, 140 CFM.
Log Set: Ceramic fibre, 10 per set
Glass Crystals: 2-1/2 pounds of crushed glass
Vent System: 3" (76.2 mm) & 4" (101.6 mm)
co-linear aluminum flex (intake & exhaust). The
unit's thermal efficiency rating is determined under
continuous operating conditions, independent of
any installed system.

On/Off Switch

T H E
With the pilot on, turn the switch to the right to
turn the burner on. Moving the switch to the left
will turn the burner off.
• This ON/OFF switch will be located on the
lower left-hand side of the appliance as
shown above.
• This ON/OFF switch overrides the remote
functionality. Ensure switch is left in ON
position when using the remote control.