Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance
to the difference between the set point temperature and the actual room
temperatures. As the room temperature gets closer to the set point the
Smart Function will modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word
"SMART" appears to the right of the temperature bulb graphic (Fig. 11).
To adjust the set temperature, press the Up or Down Arrow Keys until the
desired set temperature is displayed on the LCD screen of the Transmitter
(Fig. 12).
Note. When Smart Thermostat is activated, manual flame height adjustment
is disabled.
Figure 11: Smart Flame Function
Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of
the fan can be controlled by the Proflame system. The fan speed can be
adjusted through six (6) speeds. To activate this function use the Mode
Key (fig.1) to index to the fan control icon (Fig. 13). Use the Up/Down
Arrow Keys (fig.1) to turn on, off or adjust the fan speed (fig. 14). A
single "beep" will confirm reception of the command.
Figure 13
Figure 12
Figure 14
owner's information
Remote dimmer control (Light)
The auxiliary function controls the AUX power outlet by the dimmable
light control. To activate this function use the Mode Key (fig. 1) to index
to the AUX icon (fig. 15 & 16).
The intensity of the output can be adjusted through six (6) levels. Use the
Up/Down Arrow Keys (Fig.1) adjust the output level (Fig. 16). A single
"beep" will confirm reception of the command.
Note: This function is available only with the IFC Control Module.
Figure 15
Figure 16
Gi33 Direct Vent Gas Insert |