Owner'sInformation; Copy Of Safety Label - Regency Fireplace Products Gi29L-NG Owners & Installation Manual

Gas insert
Table of Contents

Advertisement

owner's information
CopyofSafetyLabel
A copy of the label that accompanies each Gi29L gas insert is below.
Duplicate Serial number/Copie No de série
Gi29L Serial Label
Listed: VENTED GAS FIREPLACE HEATER/FOYER AU GAZ À ÉVACUATION
Certified to/Certifi pour :
é
CSA 2.17-2017
ANSI Z21.88-2019
CSA 2.33-2019
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
C # 4001172
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold pressure
Factory Equipped for Altitude 0-2,000ft (0-610m)
Orifice
Minimum input
17,000
Maximum input
31,500
Field Convertible for Altitude 2,000 - 4,500ft (610m-1370m) - Use Conversion Kit #311-980
Orifice
Minimum Input
16,500
Maximum Input
30,500
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
Low Setting Man. Pressure
Max. Manifold Pressure
Orifice
Minimum Input
17,000
Maximum Input
31,500
Minimum Clearances to Combustibles
from Insert/Dégagements min. combustible
Side wall /mur latéral
A
8" (203 mm)
Ceiling/Plafond
B
60" (1524 mm)
Mantel/Manteau
C
41.5" (1055 mm)
Min. Alcove Width/
Largeur min. alcôve
K
54" (1372 mm)
Max. Alcove Depth/
L
36" (914 mm)
Prof. max. alcôve
FPI Fireplace Products International, Ltd
Delta BC, CANADA
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Cet appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, conformément au National Fuel Gas
Code ANSI Z223.1, ou au CSA-B149.1 en vigueur.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
AVERTISSEMENT : Ce foyer a été converti pour être utilisé avec un foyer au gaz encastrable et ne peut être utilisé pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remises en place et que le foyer ait été homologué de nouveau par une autorité
compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only.
For use only with barrier (Part # 311-417/P) Follow installation instructions. Pour utilisation uniquement avec l'écran(Pièce n°311-417/P)
Electrical supply / Alimentation électrique 115VAC, Less than 1A, 60Hz,
CATEGORY / CATÉGORIE 1
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel
RENDEMENT
Propane Gas / Gaz propane
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Part #:
920-392a
We are constantly improving Regency units. Check the safety label on the unit
and if it is different from the copy provided here, the label on the unit is correct.
Colour:
Black on grey except what is highlighted is printed red
Size:
(File at 100%) 6.495"W x 8.66" H
Material:
2 ml silver matt polyester (DPM SMS)
Sep 23/2021:
Created draft
Importantinformation
This appliance is a millivolt standing pilot system fitted with the on demand pilot, a safety feature that in the event of seven days of inactivity shuts down
the gas valve completely by extinguishing the pilot light.
Each time the main burner shuts down the seven day timer starts again. While on standing pilot, the control valve is managed manually while the seven-
day inactivity timer is controlled by a circuit board. When the pilot light is extinguished after seven consecutive days of inactivity, the control knob will
remain in the "ON" position. The pilot cannot be relit until the pilot control knob is manually returned to the "OFF" position, restarting the ignition process.
If the unit never goes as long as seven days without a call for heat, the pilot will remain lit until it is manually shut-off. See the instructions in this manual
and on the appliance's lighting instructions plate to light or re-light the pilot.
6
| Gi29 Direct Vent Gas Insert
558
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
558
Serial No. / No de série
MODEL Gi29L-NG
ENCASTRABLE AU GAZ NATUREL
MODÈLE Gi29L-NG
Pression d'alimentation minimale
5"
WC
(1.25 kPa)
Pression de sortie (manifold) - basse
1.1"
WC
(0.27 kPa)
Pression de sortie (manifold) - max.
3.8"
WC
(0.95 kPa)
Taille de l'orifice
D bit calorifique minimal
é
#38
DMS
D bit calorifique maximal
é
Btu/h
(4.98 kW)
Btu/h
(9.22 kW)
#39
DMS
Btu/h
(4.83 kW)
Btu/h
(8.93 kW)
MODEL Gi29L-LP
ENCASTRABLE AU GAZ PROPANE
MODÈLE Gi29L-LP
11"
WC
(2.74 kPa)
Pression d'alimentation minimale
2.9"
WC
(0.72 kPa)
Pression de sortie (manifold) - basse
10.5"
WC
(2.61 kPa)
Pression de sortie (manifold) - max.
#52
DMS
Taille de l'orifice
D bit calorifique minimal
é
Btu/h
(4.98 kW)
D bit calorifique maximal
é
Btu/h
(9.22 kW)
Mantel Clearances / Dégagements manteau
s
Min. Hearth Depth/
Prof. min. âtre
Min. Hearth Width/
Largeur min. âtre
G
A
Max. Mantle Depth/
Prof. max. manteau G 12" (305 mm)
L
B
C
E
D
K
MADE IN CANADA /FABRIQUÉ AU CANADA
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.
Suivre les consignes d'installation.
Fan Part #/Pièce ventilateur 911-071/P
63.88%
62.33%
OnDemandPilot(SevenDaySafetyTimer)
For the State of Massachusetts, installation and repair must be
done by a plumber or gas fitter licensed in the Commonwealth
of Massachusetts.
For the State of Massachusetts, flexible connectors shall not
exceed 36 inches in length.
For the State of Massachusetts, the appliance's individual manual
shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon
monoxide alarm in accordance with NFPA 720 and a CO alarm
with battery back up in the same room where the gas appliance
is installed
To find the safety label, remove faceplate from the front of your
unit (see manual). The safety label is located below the glass
D 12" (305 mm)
(see picture).
E 36" (914 mm)
DO NOT REMOVE THE LABEL FROM THE UNIT.
920-392a
.
Safety label location

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gi29l-lp

Table of Contents