Regency Fireplace Products Gi33LE Owners & Installation Manual page 71

Gas insert
Hide thumbs Also See for Gi33LE:
Table of Contents

Advertisement

5. Disconnect the green, orange and yellow cables from the valve.
5. Disconnect the green, orange, and yellow cables from the valve
Do not use the ground lug
on top of the valve
Disconnect
6. Remove tray fastener by removing 1 phillips head screw as shown below,
6. Remove tray fastener, slide out IFC tray and disconnect the pilot wires
slide out IFC tray and disconnect the pilot wires marked X2 & X3 on
and motor wire.
IFC and motor wire marked X6 on IFC.
Pilot Wires
Motor Wire
Tray Fastener
Warning: Ensure wires are tucked back
into place and not touching the firebox
base after servicing.
Wires must be secured by gray clips
when reinstalling.
7. Disconnect the incoming gas ex line from the ball valve. Slide the pilot wires through the grommet to remove.
7. Disconnect the incoming gas flex line from the ball valve. Slide the pilot
wires through the grommet to remove.
Remove pilot wires
from grommet
8. Remove the remaining 12 screws and lift the valve tray out.
8. Remove the remaining 12 screws and lift the valve tray out
9. Remove the 2 screws from each side of the valve and disconnect pilot gas line to remove valve.
9. Remove the 2 screws from each side of the valve and disconnect pilot
gas line to remove valve.
10. Reverse steps 9-1 to replace with new gas valve assembly.
maintenance
Disconnect gas ex line
Gi33 Direct Vent Gas Insert |
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gi33le-ngGi33le-lp

Table of Contents