installation

Leveling Legs Adjustment

The leveling of the appliance must be done prior to hooking up gas
line and vent system.
1. The leveling bolts can be installed with bolts from above or below
(preferred method) to level the appliance. If choosing to go above,
follow steps below. If choosing to go from below, see step 5. From
the back of the unit, remove the six screws, then lift the fan mount
plate out.
2. Screw the 2 2-1/2'' (64 mm) bolts supplied inside manual package to
the 2 nutserts located at the rear corners of appliance. Using a 7/16"
wrench or socket, tighten or loosen the bolts as needed. The rear
bolts can be adjusted up to 2-1/8".
3. Reinstall the fan mount plate.
24
| Gi33 Direct Vent Gas Insert
4. The front leveling bolts can be accessed from the front of the insert, on
the bottom left and right sides. Once it is in position, adjust the bolts to
ensure the appliance is level and won't rock.
5. From below: The bolts can be flipped around and installed from the bot-
tom of the insert for extended length. Once it is in position, adjust the
bolts to ensure the appliance is level and won't rock.