Appendix A Wire The Micro Motion 5700 To The Micro Motion 3100 Transmitter - Emerson Micro Motion 5700 Instruction Manual

Transmitters with configurable inputs and outputs
Table of Contents

Advertisement

Installation Manual
MMI-20027478
A
Wire the Micro Motion 5700 to the
Micro Motion 3100 transmitter
Prerequisites
Set up the transmitter channel configuration to DO before wiring.
Use active high and internal power.
Use wire size 24 AWG (0,25 mm
Procedure
Tie the three ground pins of the 5700 together and then land on A14 of the 3100. The
ground pins are even numbers: 4, 6, and 8.
Example (see the following figure): Use relay 1 (C) and 2 (B) with Channels B and C, then
connect terminal 2 and 4 together from 5700 and land on A14.
Figure A-1: 5700 to 3100 - screw-type or solder-tail connector
K3
F3
This graphic sets Channel B, configured as digital output (DO)1, to relay 1. If a different
channel is assigned to DO, wire any DO to any relay.
A. Relay 3, DO 3 pins 6 and 7, C18
B. Relay 2, DO 2 pins 5 and 6, C16
C. Relay 1, DO 1 pins 3 and 4, C14
D. Channel D
E. Channel C
F. Channel B
Installation Manual
Wire the Micro Motion 5700 to the Micro Motion 3100 transmitter
K2
A
J 3
T5A 250V
F2
T5A 250V
DS3
C
A
DISC
OUT 3
IEC 127-2
IEC 127-2
2
) to 16 AWG (1,5 mm
K1
B
C
J 2
J 1
F1
T5A 250V
DS2
C
A
DISC
OUT 2
IEC 127-2
April 2022
2
).
MODEL 3300/3500
TERMINAL
CONNECTION
A14
C18
C16
C14
J 4
DS1
C
A
DISC
OUT 1
57