Water Pressure Switch Replacement - Cornelius FRUITISTA 3 Service Manual

Fruitista viper 3 flavor
Table of Contents

Advertisement

Viper Service Manual
W
P
ATER
RESSURE
Publication Number: 621360041TBSER
Syrup
Pressure
Switch
Figure 52. View of Syrup Pressure Switch and Valve
Step
1
Disconnect power to the unit
2
Remove the appropriate side panel.
3
Turn off the syrup supply to the unit.
4
Drain the syrup from the system.
5
Disconnect the wires on the pressure switch.
6
Remove the switch, using two wrenches.
7
Replace the switch with a new unit.
8
Reverse the procedure to install the new switch.
9
Restore the syrup supply and check for leaks.
10
Check switch operation.
S
R
WITCH
EPLACEMENT
The water pressure switch, shown in Figure 53, can be viewed from the rear of
the unit. Access to the switch is obtained by removing the left side panel of the
unit, when viewed from the rear. To replace the water pressure switch, perform
the procedure in Table 55.
Water
Pressure
Switch
Figure 53. View of Water Pressure Switch
Table 54.
Action
- 58 -
© 2010-2011, IMI Cornelius Inc.

Advertisement

Table of Contents
loading