Viscosity Setup Menu - Cornelius FRUITISTA 3 Service Manual

Fruitista viper 3 flavor
Table of Contents

Advertisement

Viper Service Manual

Viscosity Setup Menu

Publication Number: 621360041TBSER
Step
Action
1
Set defrost lockout
2
Select DAY
3
Set DAY
4
Select DEFROST LOCK 1
5
Set hour field
6
7
Set minute field
8
9
Select AM/PM field
10
11
Select DEFROST LOCK 2
12
Select DEFROST LOCK 3
When the defrost lockout settings are complete, press the BACK button to save
the settings and return to the Select menu, shown in Figure 13.
The viscosity maintained in the freeze barrels depends on the type of product
being served. Some products are served best at a higher viscosity, while others
require a lower viscosity for best quality. The Viscosity menu, shown in Figure
17, allows the user to adjust the viscosity in each barrel to the optimum setting
for each type of syrup.
VISC
#1 VISC RANGE 6 48-110
#2 VISC RANGE 6 48-110
SETUP
12:51P
MAR 04
BACK
Figure 17. Viscosity Setup Screen
Refer to the Installation manual for the recommended settings based on syrup type.
Step
Action
1
Set viscosity range
2
Select barrel
3
Select range field
- 24 -
Table 17.
Procedure
Open Events Setup menu, shown in Figure 16
The DAY field is highlighted.
Use the + and - buttons at the bottom of the display to
set the desired day or all days.
Use the up and down arrows to highlight DEFROST
LOCK 1.
Use left and right arrows to select hour field
Use the + and - buttons at the bottom of the display to
set the desired hour.
Use left and right arrows to select minute field
Use the + and - buttons at the bottom of the display to
set the desired minute (in 15 min. increments).
If the 12 hour clock option is selected, use the left and
right arrows to select the AM/PM field.
Use the + button at the bottom of the display to set the
AM/PM field.
Repeat Steps 2 through 10 for the DEFROST LOCK 2
time, if desired.
Repeat Steps 2 through 10 for the DEFROST LOCK 3
time, if desired.
ALL
-
+
Table 18.
Procedure
From the Setup screen (Figure 13), open the Viscosity
Setup screen, shown in Figure 17.
Use the Up and Down arrows to highlight the desired
barrel.
Use Left and Right arrows to select range field
© 2010-2011, IMI Cornelius Inc.

Advertisement

Table of Contents
loading