Figure 2C. Wiring Diagram For The Aquapure - Jandy APUREM Installation And Operation Manual

Table of Contents

Advertisement

Jandy
AquaPure
/PureLink™ Power Center and Cell Kit
®
®
RIBBON CABLE TO
USER INTERFACE
CHLORINE GENERATOR
USER INTERFACE
Flow, Salinity, Temp Sensors
To Chlorine Generator Cell
Pool Pump Timer
Circuit Breaker
Panel
9
240 VAC
Line 1
Line 2
50/60 Hz
3 wire
Ground
Figure 2c.
Wiring Diagram for the AquaPure
The power pack must be interlocked/interconnected with the pool pump motor power source to ensure
that the chlorinator only operates when the pool pump is operating. The flow sensor feature of the
chlorinator cell is intended to be used as a backup only and should not be used as the sole source of flow
detection.
|
Installation and Operation Manual
Power Center Wiring Diagram
PRIMARY
CHLORINE GENERATOR
TRANSFORMER
CHLORINE GENERATOR
POWER INTERFACE
SECONDARY
BLACK
Factory wired for 240 VAC service; Middle primary
BLK/RED
wires connected together. If electrical service is
BLK/WHT
120VAC, the power supply must be modified.
BLK/YEL
12
3
6
Load 2
Load 1
Ground (Chassis)
Filter Pump
(240 VAC)
System
®
J12
J13
J11
Use Copper Conductors Only – Rated for 90°C Minimum
Re-wired for
120 VAC
WARNING
ENGLISH
ENGLISH
LOW VOLTAGE RACEWAY
View of chlorine generator PCB
shown with transformers and
components located behind front
face plate.
HEAT SINK
L - BRACKET
HIGH VOLTAGE
To Earth
Bonding Point
BLK/WHT
BLK/RED
BLK
BLK/YEL
Load 2 (Neutral)
Load 1 (Hot)
Ground (Chassis)
Page 11
Page 11
To Earth
Bonding Point

Advertisement