Wiring To A Jandy Aqualink Rs; Wiring Multiple Aquapure Units To A Jandy Aqualink Rs - Jandy AquaPure APURE700 Installation And Operation Manual

Aquapure electronic chlorine generator
Table of Contents

Advertisement

3.6.1

Wiring to a Jandy AquaLink RS

In the AquaLink RS Power Center, wire the AquaPure power directly to the LOAD SIDE of the Filter Pump
relay (see Figure 11).
To Filter Pump
240 VAC
Figure 11.
Wiring AquaPure Power to an AquaLink RS Power Center
The Jandy AquaLink RS and AquaPure use a four (4) wire connection to communicate and can be wired up
to 500 feet apart. Any outdoor rated four (4) conductor cable, minimum 22 AWG, can be used. Locate the
appropriate screw terminals on the circuit board according to Figure 12. Wire the AquaPure from the red 4-
pin terminal bar to the AquaLink RS red 4-pin terminal bar (see Figure 12).
NOTE The screw terminals are removable to aid in installation.
IMPORTANT
Attach the AquaPure wires to the like-numbered screw terminals on both the AquaPure and AquaLink
RS as shown in Figure 12.
Figure 12.
Wiring an AquaPure to an AquaLink RS Control System Network
3.6.2

Wiring Multiple AquaPure Units to a Jandy AquaLink RS

Only one AquaPure unit can be connected to the AquaLink RS network. Additional AquaPure units may be
wired to the Filter Pump relay, but not to the AquaLink RS red, 4-pin terminal bar.
AquaLink RS Power Center
Filter Pump Relay
Aux. 3 Relay
Red, 4-Pin
Terminal Bar
4 3 2 1
OPTIONAL
Jandy
Power Center
To Breaker
Panel
1
2
3
4
RED BLK YEL GRN
AquaLink
T est
Switches
Flow
T est P oints
Sensor
A t o K
R
H
S
ORP
Red BLK YEL GRN
Aux Board
24 VAC
F ront PCB
R evers e Side
AquaPure
(Master)
Page 15
To AquaPure
(240 VAC)