3.5 Model Configuration

The chlorine generator Power Interface Board (PIB) is configured as a 1400 model by factory default.
However, the Power Interface Board can be configured as a 700 model.
To configure the board as a 700 model, use cutting pliers to cut the JL1 jumper as shown in Figure 9.
Heat Sink
L-Bracket
Chlorine Generator Power
Interface Board
(PIB)
Figure 9.
Chlorine Generator Power Interface Board (PIB)
3.6 Installation of the Chlorine Generator User Interface on an AquaLink
1.
On the chlorine generator User Interface Board (UIB), connect one end of the ribbon cable to the 16-
pin J1 connector as shown in Figure 10.
2.
Connect the other end of the ribbon cable to the 16-pin J1 connector on the Power Interface Board
(PIB).
3.
Attach the chlorine generator User Interface Board (UIB) to the bezel using the four (4) screws
provided.
J1 Connector,
Chlorine Generator
Power Interface
Board
Ribbon Cable
Figure 10.
Installation of the User Interface
L-Bracket
Jandy
AquaPure
/PureLink™ Power Center and Cell Kit
®
®
J1 Connector,
User Interface
|
Installation and Operation Manual
Cut JL1 Jumper to
configure board as
Model AP700
RS or PDA Bezel
®
Screws (4)
2 1
4 3