Blind actuator
Upper end position has been reached:
■
Move hangings to lower end position in manual mode.
■
Move hangings to upper end position in manual mode.
Operation times have been saved.
The Venetian blind actuator saves the operation times permanently.
Without saved operation times the Venetian blind actuator generates an in-
ternal "Invalid position" message for each output that can be read out.
During operation the Venetian blind actuator adjusts itself to changed blind
travelling times, e.g. caused by ageing of the motors. The slat operation time
is taken into account here. The changed times are only saved permanently in
continuous manual mode.
8
Technical data
Supply
Rated voltage
Order no. 2154 00
Order no. 2160 00
Order no. 2152 00
Order no. 1039 00
Order no. 2161 00
Mains frequency
Order no. 2154 00
Order no. 2160 00
Order no. 2152 00
Order no. 1039 00
Order no. 2161 00
Power loss
Order no. 2154 00
Order no. 2160 00
Order no. 2152 00
Order no. 1039 00
Order no. 2161 00
Ambient conditions
Ambient temperature
Storage/transport temperature
Installation width
Order no. 2154 00
Order no. 2160 00
32560272
108707200
27.04.2023
DC 12 ... 48 V =
AC 230 / 240 V ~
AC 230 / 240 V ~
AC 230 / 240 V ~
AC 230 / 240 V ~
—
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
max. 1 W
max. 4.5 W
max. 4.5 W
max. 4.5 W
max. 6 W
-5 ... +45°C
-25 ... +70 °C
72 mm / 4 HP
72 mm / 4 HP
14 / 18