Examples - Time-Dependent Battery Control - Fronius xPrimo GEN24 4.0 Plus Operating Instructions Manual

Table of Contents

Advertisement

The following values can be selected for the rules of the time-dependent battery
control:
-
-
-
-
The timing, when the rule applies, is set in the
ing from the "Weekdays".
It is not possible to define a time window over midnight (00:00).
Example: 2 entries are needed to set a regulation from 22:00 to 06:00: "22:00 -
23:59" and "00:00 - 06:00".
Examples -
The examples below serve to explain the energy flows. Efficiency levels are not
Time-dependent
taken into account.
battery control
Example: Battery system
PV system available power
Power into the battery
Power output (AC) of the inverter
Target value set at feed-in point
Infeed into the public grid
Consumption in home
Example: Battery system without photovoltaics, including second producer in
the house
Power into the battery
Power consumption (AC) of the inverter
112
"Max charging power"
The battery is charged with the value set in the input field "Power" at most.
"Min charging power"
The battery is charged with the value set in the input field "Power" at minim-
um.
"Max discharge power"
The battery is discharged with the value set in the input field "Power" at
most.
"Min discharge power"
The battery is discharged with the value set in the input field "Power" at min-
imum.
1000 W
500 W
-
+
500 W
"Time"
input fields and by select-
TARGET: 0W
6
0 0 1
7
1000 W
500 W
500 W
0 W
0 W
500 W
0 W
500 W
1500 W
1500 W

Advertisement

Table of Contents
loading

Table of Contents