Fronius xPrimo GEN24 4.0 Plus Operating Instructions Manual page 172

Table of Contents

Advertisement

AC input/output data
Max. output current
Current (inrush)
Nominal frequency
Nominal frequency for Full Backup
Initial short circuit alternating cur-
rent / phase I
Total harmonic distortion
Power factor cos phi
Max. permitted mains impedance Z
at PCC
Maximum output fault current / dura-
tion
AC output data PV Point
Max. output power
Rated power
Nominal output current
Nominal mains voltage
Nominal frequency
Switching time
Power factor cos phi
AC output data Full Backup
Max. output power
Rated power
Nominal output current
Nominal mains voltage
Nominal frequency for Full Backup
Switching time
Power factor cos phi
General data
Maximum efficiency
European efficiency (U
European efficiency (U
European efficiency (U
Self-consumption at night
Cooling
172
6)
K
2)
4)
2)
2)
mpp nom
mpp max
mpp min
max
1 ~ NPE 220 V / 230 V / 240 V
)
)
)
Controlled forced-air ventilation
23.7 A
20 A / 1.3 ms
1)
50 / 60 Hz
1)
53 / 63 Hz
23.7 A
< 2%
0.8 - 1 (adjustable)
None
29 A / 3 ms
4133 W (for 5 s)
3000 W
13 A
1)
53 / 63 Hz
< 90 s
0 - 1
5070 W (for 5 s)
3680 W
16 A
1 ~ NPE 220 V
1 ~ NPE 230 V
1 ~ NPE 240 V
1)
53 / 63 Hz
< 90 s
0 - 1
97.6%
97.0%
96.3%
95.6%
8.2 W

Advertisement

Table of Contents
loading

Table of Contents