AC output data PV Point
Rated power
Nominal output current
Nominal mains voltage
Nominal frequency
Switching time
2)
Power factor cos phi
AC output data Full Backup
Max. output power
Rated power
Nominal output current
Nominal mains voltage
Nominal frequency for Full Backup
Switching time
2)
Power factor cos phi
General data
Maximum efficiency
European efficiency (U
mpp nom
European efficiency (U
mpp max
European efficiency (U
mpp min
Self-consumption at night
Cooling
Protection class
Dimensions H x W x D
Weight
Inverter topology
Permitted ambient temperature
Permissible humidity
EMC emission class
DC/AC overvoltage category
(in accordance with IEC 62109-1)
Pollution degree
Sound pressure
Safety class (according to IEC62103)
1 ~ NPE 220 V / 230 V / 240 V
)
)
)
Controlled forced-air ventilation
Non-insulated transformerless
0 - 100% (incl. condensation)
3000 W
13 A
1)
53 / 63 Hz
< 90 s
0 - 1
8268 W (for 5 s)
6000 W
26.1 A
1 ~ NPE 220 V
1 ~ NPE 230 V
1 ~ NPE 240 V
1)
53 / 63 Hz
< 90 s
0 - 1
97.6%
97.1%
96.7%
96.1%
8.2 W
IP 66
530 × 474 × 165 mm
17 kg
-40 °C - +60 °C
B
2 / 3
2
42 dB(A) (ref. 20µPa)
1