Fronius Datamanager 2.0 Operating Instructions Manual

Fronius Datamanager 2.0 Operating Instructions Manual

Hide thumbs Also See for Datamanager 2.0:
Table of Contents

Advertisement

Quick Links

/ Perfect Charging / Perfect Welding / Solar Energy
Operating instructions
Fronius Datamanager 2.0
Fronius Datamanager Box 2.0
42,0426,0191,EA 017-23122021
Fronius prints on elemental chlorine free paper (ECF) sourced from certified sustainable forests (FSC).

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Datamanager 2.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fronius Datamanager 2.0

  • Page 1 / Perfect Charging / Perfect Welding / Solar Energy Operating instructions Fronius Datamanager 2.0 Fronius Datamanager Box 2.0 42,0426,0191,EA 017-23122021 Fronius prints on elemental chlorine free paper (ECF) sourced from certified sustainable forests (FSC).
  • Page 3: Table Of Contents

    General Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius CL: Installing and Connecting Antennas Fronius IG USA, Fronius IG Plus USA, Fronius IG Plus V USA: Installing and Connecting Anten- Installing Fronius Datamanager 2.0 in Fronius Solar Net Safety Installing Inverters with Fronius Datamanager 2.0 in Fronius Solar Net...
  • Page 4 Connecting to Fronius Datamanager 2.0 via the Internet and Fronius Solar.web General Function Overview Requirements Accessing Data from Fronius Datamanager 2.0 via the Internet and Fronius Solar.web Current Data, Services, and Settings on Fronius Datamanager 2.0 The Fronius Datamanager 2.0 Website Fronius Datamanager 2.0 Website – Overview...
  • Page 5 Inverter Settings – Fronius Sensor Cards Sensor Cards Settings – Counter General Fronius Smart Meter Connecting the Fronius Smart Meter to the Fronius Datamanager 2.0 S0 Inverter Settings – DNO Editor General DNO Editor – IO Control Connection example UC Editor – AUS – Demand Response Modes (DRM) UC Editor –...
  • Page 7: General Information

    General information...
  • Page 9: General

    (Fronius Datamanager Box 2.0, e.g., for inverters without plug-in card slots or for photovoltaic systems with a separate Fronius Datamanager 2.0) Provided that the inverter is not fitted as standard with the Fronius Datamanager 2.0, ex- isting inverters can be upgraded with the Fronius Datamanager 2.0 plug-in card.
  • Page 10: Inverter Software Required

    Fronius Datamanager Box 2.0 in the Fronius Solar Net ring. The Fronius Datamanager 2.0 plug-in card and the Fronius Com Card must not be used together in one inverter.
  • Page 11: Notes Regarding Radio Certification

    The relevant inverter software version can be downloaded for free from our homepage (http://www.fronius.com). If you have any questions, please contact pv-support@fronius.com. Notes regarding The Fronius Datamanager 2.0 plug-in card and Fronius Datamanager Box 2.0 are radio certification equipped with a wireless module. Wireless modules in the USA require FCC certification: This device conforms to the limit values for a Class B digital device, pur- suant to Part 15 of the FCC regulations.
  • Page 12: Scope Of Supply

    IMPORTANT! If the three-part sticker label included in the scope of supply for the Labels Datamanager 2.0 has not already been affixed to the inverter at the factory, this must be done now. Position of the sticker label on the inverter:...
  • Page 13: Configuration Examples

    PC/laptop WLAN IMPORTANT!When linking an inverter with Fronius Datamanager 2.0 to a PC, one Froni- us Solar Net termination plug must be connected at each free IN or OUT connection. Linking Inverters with a Fronius Datamanager 2.0 Plug-in Card to Other Invert-...
  • Page 14 When linking several DATCOM components to Fronius Datamanager 2.0: Use the data cable to connect the IN connection socket of Fronius Datamanager 2.0 with the OUT connection socket of the next DATCOM component. A Fronius Solar Net ter- mination plug must be inserted into the empty IN connection socket of the last DATCOM component.
  • Page 15 DATCOM components must be cabled from the IN connection socket to the OUT connection socket of the next DATCOM component. Fronius Solar Net termination plugs must be inserted into empty IN or OUT connection sockets of the last DATCOM components.
  • Page 16: Calculating The Data Volume

    Calculating the data volume General When operating Fronius Datamanager 2.0, data is generated and needs to be transmit- ted online. In order to select a suitable internet connection it is necessary to calculate the data volume. The following data volume calculation provides an overview of the amount of data gener- ated when operating Fronius Datamanager 2.0.
  • Page 17: Calculation Examples

    If the functions have been deactivated, no data volume is generated. A certain data volume is also required to update the Fronius Datamanager 2.0 firmware. This data volume depends on the size of the relevant update package and cannot there- fore be taken into account for any advance calculation of the data volume.
  • Page 18 Example 2 - large-scale system Archived data are sent to Fronius Sol- ar.web; 120 minutes transfer time; + 0.6 KB/min x 120 min = 72 KB Inverters operate 14 h/day; 5 minutes storage interval; + (173 memory sectors/day x 4 KB)
  • Page 19: General Information For The Network Administrator

    Solar.web, then a gateway address and a DNS server address must also be entered. Fronius Datamanager 2.0 uses the gateway address to access the internet. The IP ad- dress of the DSL router can be used as a gateway address, for example.
  • Page 20: Sending Service Messages Via A Dsl Internet Connection

    However, an internet connection is required to use Fronius Solar.web and send service Solar.web and messages. Sending Service Messages Fronius Datamanager 2.0 cannot connect itself to the internet. A router must be used for a DSL connection to the internet.
  • Page 21: Controls, Connections And Indicators

    Controls, connections and indicators Safety WARNING! Danger due to incorrect operation. This can result in severe personal injury and damage to property. ▶ Do not use the functions described here until you have fully read and understood the Operating Instructions. ▶...
  • Page 22: Controls, Connections, And Indicators

    Fronius IG Plus Fronius Galvo Fronius IG Plus V Fronius Symo Fronius IG Plus A Fronius Primo Fronius CL Fronius CL USA Fronius IG 300 - 500 (13) (8) (9) (11) (12) Function IP switch For changing the IP address:...
  • Page 23 (DHCP) The IP address can be set on the Fronius Datamanager 2.0 website. In the case of the Fronius Datamanager 2.0 plug-in cards, the IP switch is located underneath the LEDs and is separate in the case of the Fronius Datamanager Box 2.0.
  • Page 24 Lights up green: there is an active connection within Fronius Solar Net Lights up red: there is an interrupted connection within Fronius Solar Net Does not light up: the Fronius Datamanager 2.0 is in secondary mode LAN Connection Ethernet interface with blue color marking for connecting the Ethernet cable...
  • Page 25 COM components (e.g., inverters, sensor cards) For the Fronius Datamanager 2.0 with Fronius Com Card function only! (for Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Froni- us CL, Fronius CL USA, Fronius IG 300–500 inverters)
  • Page 26: Schematic Connection Of I/Os

    Current limit Solar Net IN connection socket 115–230 V AC: Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Fronius CL, Fronius CL USA, Fronius IG 300 - 500 12.8 V DC: Fronius Galvo, Fronius Symo, Fronius Primo...
  • Page 27 When the supply is via an external power supply, the external power supply must be gal- vanically isolated. 10.7 V DC: Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Fronius CL, Fronius CL USA, Fronius IG 300 - 500 12.8 V DC:...
  • Page 28: Technical Data

    = 46 kOhm Switching capacity of digital outputs when 3.2 W supplied by the Fronius Datamanager 2.0 plug-in card Fronius IG, Fronius IG Plus, Fronius IG 10.8 V Plus V, Fronius IG Plus A, Fronius CL, Fronius CL USA, Fronius IG 300–500...
  • Page 29 Given sufficient power supply from Fronius Solar Net, the green LED lights up on every DATCOM component. If the green LED does not light up, the power supply unit available from Fronius should be inserted into the 12 V power supply connection socket of an external DATCOM component.
  • Page 31: Installing Fronius Datamanager 2.0

    Installing Fronius Datamanager 2.0...
  • Page 33: Inserting Fronius Datamanager 2.0 Into An Inverter

    Fronius Symo does not matter Fronius Primo does not matter If an ENS plug-in card is inserted in the ENS slot: insert the Fronius Dataman- ager 2.0 in the next slot to the right of the ENS slot. IMPORTANT!
  • Page 34 The next slot must be kept free. Never remove an existing ENS plug-in card.
  • Page 35: Installing And Connecting Wlan Antennas

    Connect the antenna cable to the an- tenna socket on the Fronius Dataman- ager 2.0 plug-in card Run the antenna cable out through the DATCOM opening on the inverter...
  • Page 36 Attach the lock washer and screw on 0,9 Nm the hex nut Screw on the antenna Fronius IG USA, Fronius IG Plus USA, Fronius IG Plus V USA: In- stalling and Con- necting Antennas...
  • Page 37 CAUTION! Danger of short circuit caused by loose metal parts from knockouts. Loose metal parts in the inverter may cause short circuits when the inverter is powered up. When removing knockouts, make sure that ▶ no loose metal parts fall into the inverter, ▶...
  • Page 38 8 Nm 5.90 ft. lb. *Bending radius of the antenna cable: at least 25.4 mm/1 in. 0.9 Nm 8 in-lb...
  • Page 39: Installing Fronius Datamanager 2.0 In Fronius Solar Net

    The Ethernet cable should only be inserted into the LAN connection socket (colored blue). ▶ The Fronius Solar Net cable should only be inserted into the Fronius Solar Net IN connection socket (colored red). Installing Invert- Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Fronius CL, ers with Fronius Fronius CL USA, Fronius IG 300–500:...
  • Page 40: Installing Fronius Datamanager Box 2.0 In Fronius Solar Net

    If only one inverter with Fronius Datamanager 2.0 is linked to a PC: Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Fronius CL, Froni- us CL USA, Fronius IG 300 - 500: Insert the Fronius Solar Net termination plug into the Fronius Solar Net IN connec-...
  • Page 41 Insert the Fronius Solar Net cable into the Fronius Solar Net OUT connection socket of the Fronius Datamanager Box 2.0 Insert the Fronius Solar Net cable into the Fronius Solar Net IN connection socket of the inverter as per the inverter operating instructions...
  • Page 42: Fronius Solar Net Cabling

    DATCOM components will hereinafter be referred to as Fronius Solar Net clients. Fronius Solar Net The data connection for the Fronius Solar Net client is a 1:1 connection using 8-pin data Client Cabling cables and RJ-45 plugs.
  • Page 43: Preassembled Data Cables

    ISO/IEC 11801:2002 internationally TIA/EIA 568 for North America Rules for use of copper cables apply. Preassembled The following preassembled data cables are available from Fronius: data cables CAT5 cable 1 m ... 43,0004,2435 CAT5 cable 20 m ... 43,0004,2434 CAT5 cable 60 m ... 43,0004,2436 The cables listed above are 8-pin, 1:1 LAN network cables, shielded and twisted, includ- ing RJ 45 plugs.
  • Page 44: Installing Fronius Datamanager 2.0 - Overview

    IMPORTANT! Inverters Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Fronius CL, Fronius CL USA, and Fronius IG 300–500 must always be loc- ated at the beginning or end of the Fronius Solar Net ring.
  • Page 45 Switch the device to service mode Inverter with Fronius Datamanager 2.0 plug-in card: Switch the IP switch on the Fronius Datamanager 2.0 plug-in card to position A Activate the WLAN access point via the Setup menu of the inverter (the performance of this function depends on the inverter software)
  • Page 46: Starting For The First Time Via A Web Browser

    IMPORTANT! Inverters Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Fronius CL, Fronius CL USA, and Fronius IG 300–500 must always be loc- ated at the beginning or end of the Fronius Solar Net ring.
  • Page 47 Switch the device to service mode Inverter with Fronius Datamanager 2.0 plug-in card: Switch the IP switch on the Fronius Datamanager 2.0 plug-in card to position A Activate the WLAN access point via the Setup menu of the inverter (the performance of this function depends on the inverter software)
  • Page 48 If the Technician Wizard is not run, no specifications for power reduction are set. The Solar Web Wizard must be run. If necessary, run the Technician Wizard and follow the instructions Run the Solar Web Wizard and follow the instructions The Fronius Solar.web start page appears. The Fronius Datamanager 2.0 website opens.
  • Page 49: Establishing A Connection To Fronius Datamanager

    Establishing a Connection to Froni- us Datamanager 2.0...
  • Page 51: Connecting To Fronius Datamanager 2.0 Via A Web Browser

    Browser General The connection to Fronius Datamanager 2.0 via a web browser is suitable for accessing current values with several PC users in a LAN (e.g., company networks, schools). For example, total and daily yields can be accessed and/or inverter comparisons can be made on the Fronius Datamanager 2.0 website.
  • Page 52: Connecting To Fronius Datamanager 2.0 Via The Internet And Fronius Solar.web

    Function Over- Fronius Datamanager 2.0 is connected to the internet (e.g., via a DSL router). Fronius view Datamanager 2.0 regularly logs on to Fronius Solar.web and sends its saved data every day.
  • Page 53: Current Data, Services, And Settings On Fronius Datamanager

    Current Data, Services, and Settings on Fronius Datamanager 2.0...
  • Page 55: The Fronius Datamanager 2.0 Website

    (6) Contact Send feedback (7) Settings menu (8) Other setting options Login The setting options on the website of the Fronius Datamanager 2.0 depend on the user's authorization (see section Passwords on page 65). Log in with username and password: Select the user to log in.
  • Page 56: Reset Password

    Selected menu item Menu items in Settings The Meter and DSO Editor menu items are protected menu by the service password. Other setting op- Other setting options are shown in the top right corner of the Fronius Datamanager 2.0 tions website:...
  • Page 57 Software Operating Instructions Fronius Solar Channel Expand contents: The Real-time Data/Settings menu is hidden Display notifications Language: Set the language The Fronius Datamanager 2.0 website will appear in the language set for the browser itself or in the last selected language.
  • Page 58: Current Data In Fronius Datamanager 2.0

    Current Data in Fronius Datamanager 2.0 Current Compar- Several inverters in the same photovoltaic system can be compared in the current Com- ison View parison View. The real-time inverter AC power is displayed as a percentage of the power from the solar module connected to the respective inverter (shown in a bar diagram).
  • Page 59: Services - System Information

    Services – System Information System Informa- The System Information page contains various information about the system. tion The following buttons are also available: “Datalogger restart” button Used to restart the datamanager/system monitoring “Reset to factory settings” button with the following selection options: “All settings except for the network”...
  • Page 60: Services - Network Diagnostics

    Services – Network Diagnostics Network Dia- The Services / Network diagnostics option contains functions that are useful for diagnos- gnostics ing and correcting network problems. Ping and traceroute commands can be executed. Ping command Used to determine whether or not a host is available and how much time a data transfer will take.
  • Page 61: Services - Firmware Update

    Firmware Update Establish LAN connection between PC/laptop and Datamanager via LAN Download the current firmware from the Fronius homepage Run the downloaded update file on the PC/laptop This will start a web server from which the Datamanager will download the required files.
  • Page 62 Select “Update via LAN” Enter the IP address of the PC/laptop Click on the “Run update” button The confirmation prompt for the update appears. Click on the “Yes” button The update starts and the progress is displayed as a bar and a percentage. Once the update has been carried out successfully, click on the “Apply/Save”...
  • Page 63: Services - Opening Wizards

    Services – Opening Wizards Opening Wizards Under "Open Wizards," it is possible to re-open the Solar.web Wizard and the Techni- cian Wizard and run these again.
  • Page 64: Settings - General

    Settings – General General You can enter the charge rate per kWh, the currency, and the expenses per kWh to cal- culate the yield under "Feed-in payment." The yield is shown in the current Total View. The date, hour, and minutes can be entered under "System time." Click on the "Synchronize"...
  • Page 65: Settings - Passwords

    Settings – Passwords General Access to Fronius Datamanager 2.0 is regulated by assigning passwords. Three different password types are available: the administrator password the service password the user password Passwords Administrator Password User name = admin The administrator password set during commissioning assigns the user read and write (configuration) access.
  • Page 66: Settings - Network

    Datamanager (system monitoring) in the “Host name” field. The con- nection to the Datamanager (system monitoring) can then be established using the name instead of the IP address. For example: Host name = sample_system, Domain name = fronius.com. The Datamanager (system monitoring) can be reached via the address “sample_system.fronius.com”.
  • Page 67 The Datamanager (system monitoring) is used as the access point. The PC or smart device connects directly to the Datamanager (system monitoring). Connecting to the in- ternet is not possible.
  • Page 68: Settings - Fronius Solar.web

    Fronius Solar.web is automatically sent as well. Memory capacity The Fronius Datamanager has a memory capacity of up to 5 years and 7 months for a PV system with one inverter and a save interval of 15 minutes.
  • Page 69 Logging points per day: 840 min Inverter logging points = = 56 15 min 1440 min Sensor Card logging = 96 points = 15 min Total logging points: Total logging points = (2 x 56) + (1 x 96) = 208 (2 x 56) ...
  • Page 70: Settings - Io Mapping

    (DRM) You can adjust the pins for control via DRM here: IMPORTANT! To control an inverter via DRM the inverter has to have a Fronius DRM Interface (item number 4,240,005). Assembly and installation are described in the Installation Instructions of the Fronius DRM Interface.
  • Page 71: Io Control

    DRM8 ≤ 100% Normal operation without re- striction on the Fronius DRM interface The values for Q can be adjusted in the UC Editor menu item. The nominal device output is always meant when referring to the inverter's remote con- trol capability.
  • Page 72: Settings - Load Management

    Settings - load management General The outputs I/O 0 - I/O 3 can be used to control an actuator (e.g., relay, contactor) via the load management function. A connected load can thus be controlled by assigning a power feed-dependent switch-on or switch-off point.
  • Page 73: Settings - Push Service

    This function can be used to export current and log data in different formats or with differ- ent protocols to an external server. Further information about the push service function can be found in the following Operat- ing Instructions: http://www.fronius.com/QR-link/4204102152 42,0410,2152 Fronius Push Service...
  • Page 74: Modbus Settings

    Modbus Settings General From your web browser, you can use the Fronius Datamanager 2.0 website to apply the Modbus connection settings which cannot be accessed via the Modbus protocol. Additional In- For additional information on the Modbus function, please see the following Operating In-...
  • Page 75: Limit Control

    Setting a constant reactive power "Data output via Modbus" set to "RTU" If there is a Modbus energy meter (e.g., Fronius Smart Meter) configured under Settings/ Meter in the system, it will not be possible to use the "RTU" setting.
  • Page 76: Save Or Reject Changes

    "IP address" field To limit inverter control to one or more devices, enter the IP addresses of the devices which are permitted to send commands to Fronius Datamanager in this field. Multiple entries are separated by commas. Examples: one IP address: 98.7.65.4 – control only permitted by IP address 98.7.65.4 several IP addresses: 98.7.65.4,222.44.33.1 –...
  • Page 77: Settings - Inverter

    Settings – Inverter Inverter The data for the Comparison View is defined in the "Inverter" menu. If the "visible" selection field is selected, the inverter is displayed in the Comparison View.
  • Page 78: Settings - Fronius Sensor Cards

    Settings – Fronius Sensor Cards Sensor Cards A specific channel name can be assigned to each sensor value of a Fronius Sensor Card/Box under "Sensor Cards" (e.g., Wind Speed).
  • Page 79: Settings - Counter

    (1b) Secondary meter If a Fronius Smart Meter was chosen as a secondary meter, a window will open to enter the “Description” (freely selectable) as well as a “Modbus address” field. A value is suggested automatically in the “Modbus address” field (next free address in the address...
  • Page 80: S0 Inverter

    A S0 meter must be configured at this point so that the amount of energy fed is counted. IMPORTANT! With an S0 meter at the infeed point, the meter data are not displayed in Fronius Sol- ar.web. This option is only provided for dynamic power reduction. The consumption val- ues can be detected to a limited extent when feeding into the grid.
  • Page 81 Requirements for the S0 meter: Must meet standard IEC 62053-31 Class B Max. voltage: 15 V DC Max. current when ON: 15 mA Min. current when ON: 2 mA Max. current when OFF: 0.15 mA Recommended max. impulse rate of S0 meter: PV power kWp [kW] Max.
  • Page 82: Settings - Dno Editor

    Settings – DNO Editor General In the "UC Editor" menu item, settings relevant to electricity retailers are made. An effective power limit in % and/or a power factor limit can be set. IMPORTANT! Settings in the "UC Editor" menu item may only be made by staff trained to do so! The service password must be entered for the "UC Editor"...
  • Page 83: Connection Example

    The ripple control signal receiver and the Fronius Datamanager 2.0 plug are connected to one another using a 4-pin cable in accordance with the connection diagram. For distances of greater than 10 m between the Fronius Datamanager 2.0 and the ripple control signal receiver, a shielded cable is recommended.
  • Page 84: Uc Editor - Aus - Demand Response Modes (Drm)

    UC Editor – AUS IMPORTANT! To control an inverter via DRM the inverter has to have a Fronius DRM – Demand Re- Interface (item number 4,240,005). sponse Modes Assembly and installation are described in the Installation Instructions of the Fronius (DRM) DRM.
  • Page 85: Uc Editor - Control Priorities

    If Fronius Smart Meter or S0 inverter has been selected under the "Meter" menu item: max. energy fed into the grid "Hard Limit" - If this value is exceeded, the inverter switches off within max. 5 seconds. This value must be higher than the value set for "Soft Limit".

This manual is also suitable for:

Datamanager box 2.0