DC input data battery
Max. voltage
Min. voltage
Max. current
Max. output
DC inputs
AC input/output data
Nominal output power (P
Max. output power
Rated apparent power
Nominal mains voltage
Min. mains voltage
Max. mains voltage
Max. output current
Current (inrush)
Nominal frequency
Nominal frequency for Full Backup
Initial short circuit alternating cur-
rent / phase I
Total harmonic distortion
Power factor cos phi
Max. permitted mains impedance Z
at PCC
Maximum output fault current / dura-
tion
AC output data PV Point
Max. output power
Rated power
Nominal output current
Nominal mains voltage
Nominal frequency
Switching time
Power factor cos phi
AC output data Full Backup
Max. output power
Rated power
Nominal output current
168
)
nom
6)
K
2)
4)
2)
1 ~ NPE 220V / 230V / 240 V
max
1 ~ NPE 220 V / 230 V / 240 V
455 V
150 V
22 A
3000 W
1
3000 W
3000 W
3000 W
1)
155 V
1)
270 V
19.4 A
20 A / 1.3 ms
1)
50 / 60 Hz
1)
53 / 63 Hz
19.4 A
< 2%
0.8 - 1 (adjustable)
None
29 A / 3 ms
4133 W (for 5 s)
3000 W
13 A
1)
53 / 63 Hz
< 90 s
0 - 1
4133 W (for 5 s)
3000 W
13 A