Manual system start

Requirements

There is no energy available from the PV modules or from the public grid. If
backup power operation or battery operation are not possible (e.g. deep dis-
charge protection of the battery), the inverter and battery switch off.
Notification of
Status codes about the inactive state of the battery are displayed on the user in-
system shut-
terface of the inverter or sent via Solar.web by means of SMS or e-mail (only if
down
notification via Solar.web is configured accordingly).
Manual battery
As soon as energy is available again, the inverter starts operation automatically;
start after sys-
however the battery must be started manually. The switch-on sequence must be
tem shutdown
observed for this, see chapter
Starting backup
The inverter requires energy from the battery to start backup power operation.
power operation
This is done manually on the battery; further information on the power supply for
after a system
restarting the inverter via the battery can be found in the battery manufacturer's
shutdown
Operating Instructions.
Suitable batteries
on page 26.
29