SERIES 1500 LIQUID TURBINE METER
Planned maintenance
September 2020
88
78
www.Daniel.com
Figure 9-16: Journal installation
A. Downstream cone
3. Clean the bearing inside surface and install the rotor in the same direction label A or
B (as disassembled). Slide the rotor onto the shaft and place it on the journal.
Figure 9-17: Rotor installation
A. Downstream cone
4. Place the thrust washer in the counterbore of the upstream cone face, polished side
of the thrust washer out. Place the end of the shaft into the center hole in the
upstream spring clip assembly cone and push the upstream and downstream spring
clip assemblies together until the cones/thrust washers contact the journal.
Figure 9-18: Thrust washer and spring clip assembly installation
A. Downstream cone
B. Upstream cone
User manual
P/N 3-9008-507
Daniel Series 1500 Liquid Turbine Meter, NPS 1-2.5