Important
The security latch prevents the removal of the LME cover in a flameproof
environment.
3. Unscrew the end cap and remove it from the housing.
4. Unplug one or two ¾-14 NPT ports (as required) and install the conduit (provided by
the customer) to the enclosure and tighten.
5. Install the electronics according to
Daniel if the preamplifier acquired is other than a dual channel preamplifier.
SHOCK AND EXPLOSION HAZARD
Verify that the LME and/or RME is grounded.
Failure to comply may cause death, serious injury and/or equipment damage.
6. Screw the end cap to the housing. Hand-tighten, only if required.
7. Install the security latch.
User manual
WARNING
Installation procedure
Wiring and cable
connections. Consult with
USER MANUAL
September 2020
67