Table 2-4: 2415 Intrinsically safe preamplifier performance
Parameter type
Inputs
Outputs
Construction
Table 2-5: 1815B Zero crossing preamplifier performance
Parameter type
Inputs
Outputs
Construction
Table 2-6: 1817X Bi-directional preamplifier performance
Parameter type
Inputs
User manual
36
www.Daniel.com
Operating conditions and specifications
Description
Supply voltage: 13-25 Vdc @ ≤12 mA
Sensor type: Reluctance
Signal: Sine wave
Preamplifier sensitivity:
60 mVpp
10Hz - 1KHz (60mVpp)
10Hz - 3KHz (115mVpp)
10Hz - 5KHz (200mVpp)
Temperature range: -40 ºC to 85 ºC (-40 ºF to 185 ºF)
Powered pulse output:
Type: Square wave
Frequency range: ∼5 Hz to 5 kHz
Amplitude: 0 to 5 V
Delrin housing
Solid epoxy encapsulation
Description
Supply voltage: 14-30 VDC
Sensor type: Reluctance
Signal: Sine wave
Preamplifier sensitivity: 40 mVpp
Temperature range: -40 ºC to 85 ºC (-40 ºF to 185 ºF)
Powered pulse output:
Type: Square wave
Frequency range: ≤ 5 kHz
Amplitude: 0-12 V
Delrin housing
Solid epoxy encapsulation
Description
Supply voltage: 11.5-36 VDC
Sensor type: Reluctance
Signal: Sine wave
Preamplifier sensitivity: 40 mVpp
Temperature range: -40 ºC to 85 ºC (-40 ºF to 185 ºF)