Display And Keyboard; Display Fields And Symbols Description - ABB TRIO-5.8-TL-OUTD-S Product Manual

Table of Contents

Advertisement

D
isplay and keyboard
D
isplay fields and symbols description
b01
b02 b03 b04
b11
Ref. Description
b01 Indicates transmission and reception of data through the RS485 line
b02 Indicates presence of the RS485 communication line
b03 Indicates presence of the radio communication line (radio module board installed)
b04 Indicates presence and readiness of the Bluetooth communication line (NOT available)
b05 Indicates presence and readiness of the WiFi communication line (NOT available)
b06 Reports an active power derating for out-of-range input voltage or power restrictions set by the grid
manager or by the display
b07 Reports a power derating due to high internal temperature
b08 Instantaneous power placed on the grid
b09 MPPT SCAN function active
b10 Text lines to cyclically display the inverter parameters, error codes, and for menu navigation
b11 Graph of power introduced to grid (from 0 to 100%). Timescale can be set to 8/16/24 hours
b12 Displays the total energy from the inverter installation
b13 Shows the energy produced throughout the day
b14 Indicates that the PV generator voltage is greater than the inverter Vstart
b15 Input voltage (DC)
b16 Input current (DC)
b17 Indicates the DC/DC input circuit (Booster)
b18 Indicates the DC to AC conversion circuit
b19 Output voltage of phase highlighted
b20 Output current of phase highlighted. At the end of the currents display the grid frequency (Hz) is shown
b21 Connection to the grid:
b22 State of grid voltage:
Icon absent: grid voltage not present
Flashing icon: grid voltage present but outside parameters set by the standard grid
Icon present: Grid voltage present and within parameters set by the standard grid
Main menu scrolling mode:
b23
CYCLIC: Cyclic display of the main parameters of the inverter.
LOCKED: Display locked on the screen to be constantly monitored.
b24 Indicates the channel which refers to the values of voltage and input current displayed. In the event of
independent channels, parameters are displayed cyclically (channel 1 or 2)
Using the display, operating parameters for the equipment are shown.
signals, alarms, channels, voltages, etc.
The display, when in operation, behaves dynamically, allowing cyclical
display of certain information (see relevant chapter).
b05
b06
b07
b08
b13
b12
b24
Inverter not connected /
- 68 -
b09
b10
DC
AC
b14
b15
b16
Inverter connected
6 - Instruments
b23
b19
b22
b21
b20
b17
b18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trio-7.5-tl-outd-sTrio-8.5-tl-outd-s

Table of Contents