ABB TRIO-5.8-TL-OUTD-S Product Manual page 21

Table of Contents

Advertisement

Table: Technical Data TRIO-5.8-TL-OUTD TRIO-7.5-TL-OUTD TRIO-8.5-TL-OUTD
Rated Output Frequency (f
Output Frequency Range (f
Nominal Power Factor (Cosphi
Total Current Harmonic Distortion
AC Connections Type
Anti-islanding Protection
Maximum AC Overcurrent protection
Output overvoltage protection - Varistors
Operating performance
Maximum Efficiency (η
Weighted Efficiency (EURO/CEC)
Power Supply Threshold
Stand-by Consumption
Night-time consumption
Night-time Consumption (Reactive Power)
Inverter Switching Frequency
Wired Local Monitoring (opt.) Ethernet board with webserver (opt.), PVI-USB-RS232_485 (opt.)
Remote Monitoring (opt.)
Wireless Local Monitoring (opt.)
Ambient temperature
Storage temperature
Maximum operating altitude
External environment pollution rating
Environmental Protection Rating
Overvoltage rating as per IEC 62109-1
Dimensions (H x W x D)
Safety and EMC Standards
1. The output voltage range may vary according to the grid standard of the country of installation
2. The output frequency range may vary according to the grid standard of the country of installation
3. <2W in Stand-by mode
Note. Features not specifically mentioned in this data sheet are not included in the product
)
r
...f
)
min
max
> 0.995, adj. ± 0.9 with
Pacr =5.22 kW,
)
acr
adj. ± 0.8 with max
Output protection
)
max
97.4% / -
Communication
User Interface
Environmental
-25...+60°C /-13...140°F with derating above 50°C/122°F
Relative Humidity
Noise Emission
Environmental class
Physical
Cooling System
855mm x 429mm x 237mm / 33.7" x 16.9" x 9.3" with cover open
Weight
25.0 kg / 55.1 lb
Assembly System
Safety
Safety class
Insulation level
Marking
EN62109-1, EN62109-2, AS/NZS3100, AS/NZS 60950, EN61000-6-2,
CEI 0-21, CEI 0-16, VDE 0126-1-1, VDE-AR-N 4105, G83/1, C10/11,
Grid Standard
EN 50438 (not for all national variants), RD1699, RD 1565, ABNT
50 Hz / 60 Hz
47...53 Hz / 57...63 Hz
> 0.995, adj. ± 0.9 with
Pacr =6.75 kW,
adj. ± 0.8 with max
5.8kVA
7.5kVA
< 2%
Screw terminal block max cross-section 10 mm
Complying with the local standard
10.5 A
12.0 A
4, plus gas arrester
98.0%
97.5% / -
32 W
36 W
< 15 W
<5W
55 VAR
15.8 kHz
Ethernet board (opt.),VSN300 Wifi Logger Card (Opt.),
PVI-AEC-EVO (Opt.), VSN 700 Data Logger (Opt.)
VSN300 Wifi Logger Card (opt.)
Graphic Display
-40...80°C (-40...+176°F)
0...100% condensing
< 45 db(A) @ 1 m
2000 m / 6560 ft
3
Outdoor
IP 65
Natural
II (DC input) III (AC output)
641mm x 429mm x 220mm / 25.2" x 16.9" x 8.7"
28.0 kg / 61.7 lb
Wall bracket
I
Without transformer (TL)
CE
EN61000-6-3, EN61000-3-2, EN61000-3-3
NBR 16149
- 21 -
2 - Characteristics
(2)
> 0.995, adj. ± 0.9 with
Pacr =7.65 kW,
adj. ± 0.8 with max
8.5kVA
2
15.0 A
97.5% / -
36 W
(3)
28.0 kg / 61.7 lb

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trio-7.5-tl-outd-sTrio-8.5-tl-outd-s

Table of Contents