NOTICE
Loss of license keys
Back up the license keys before the restore by dragging these to your USB restore stick via
the Automation License Manager.
After the restart of the CPU 1515SP PC2, transfer the license keys back to the device via
the Automation License Manager.
Procedure to restore the delivery state
To restore the state saved on the CFast card using the USB restore stick, follow these steps.
1. Switch off the power supply to the CPU 1515SP PC2.
2. Remove all USB drives from the CPU 1515SP PC2.
3. Connect the USB restore stick directly to the CPU 1515SP PC2.
4. Insert the CFast card into the designated slot of the CPU 1515SP PC2.
5. Switch on the power supply to the CPU 1515SP PC2.
The CPU is started.
6. To start the Boot Manager, press <Esc> while the Siemens logo is being displayed.
7. Select the list entry for the USB stick as boot medium in the Boot Manager.
8. Follow the instructions of the SIMATIC IPC Restore application.
The original software is restored.
9. Copy the restore data from the USB flash drive to the restore partition. To do this, select the
"Fill restore partition" option in the SIMATIC IPC Restore application.
Note
The restore process writes all the data stored on the USB stick to the restore partition.
In case you skip step 9 from the above instruction, the restore partition will remain empty.
11.7

Updating software

Note
When you update software (such as Windows, drivers, BIOS, etc.), always start the
CPU 1515SP PC2 in the GRUB menu in Windows mode.
Information on updating software for the respective product can be found on the Internet
(https://support.industry.siemens.com/cs/ww/en).
CPU 1515SP PC2 (F/T/TF)
Operating Instructions, 03/2023, A5E42603425-AC
Maintenance
11.7 Updating software
71