Electrical connection

Equipotential
bonding
connection
114
Electrical connection
 All electrical work must be carried out by a suitably qualified
and competent person in accordance with local and national safety
regulations.
- In the U.K. it must comply with BS 7671.
- Connection to the power supply must be made via a suitable plug
and socket which conforms to national regulations and must be
accessible for service and maintenance work after the machine has
been installed.
- For hard-wired machines, connection should be made via a suitable
mains switch with all-pole isolation which when in the off position
ensures a 3 mm gap between all open contacts.
- For increased safety, it is recommended to protect the machine
with a suitable residual current device (RCD) with a trip current of
30 mA.
- Equipotential bonding should be carried out if required.
- The mains connection cable may only be replaced by an original
Miele spare part.
- For technical data see data plate or wiring diagram supplied.
The machine must only be operated with the voltage, frequency and
fusing shown on the data plate.
This machine can be converted to a different type of power supply
in accordance with the conversion diagram and wiring diagram
supplied.
The conversion diagram and the data plate are supplied with the
dishwasher.
There is a screw connection point marked  at the back of the
appliance, to which additional equipotential bonding can be
connected.