Electrical connection

The dishwasher is "connector-ready" as
standard for connection to an earthed
socket.
The socket must be easily accessible
after the dishwasher has been installed.
If that is not possible, ensure that a
suitable means of disconnection is
provided on the installation side for
each pole.
Risk of fire from overheating.
Connecting the dishwasher to a
multi-socket adapter or to an
extension lead can overload the
mains connection cable.
For safety reasons, do not use an
extension lead or multi-socket
adapter.
The electrical installation must comply
with VDE 0100 requirements.
For safety reasons, we recommend
using a type  residual current device
(RCD) in the assigned electrical
installation for connecting the
dishwasher.
If the mains connection cable is
damaged, it must only be replaced with
a specific mains connection cable of
the same type (available from the Miele
Customer Service Department). For
safety reasons, such replacement may
only be carried out by a qualified
specialist or the Miele Customer
Service Department.
These operating instructions and the
data plate indicate the nominal power
consumption and the appropriate fuse
rating. Compare this information with
the data of the on-site electrical
connection.
If in any doubt, consult a qualified
electrician.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not
synchronised with the mains power
supply (e.g. island networks, back-up
systems) is possible. A prerequisite for
operation is that the power supply
system complies with the specifications
of EN 50160 or an equivalent standard.
The function and operation of the
protective measures provided in the
domestic electrical installation and in
this Miele product must also be
maintained in isolated operation or in
operation that is not synchronised with
the mains power supply, or these
measures must be replaced by
equivalent measures in the installation.
As described, for example, in the
current version of BS OHSAS 18001–2
ISO 45001.