5.2.2 Electrical connection

Danger
Electric shock from live components
A fatal electric shock can occur when the warewasher and its additional devices are connected to the electrical mains
supply.
Ø
The warewasher and its additional devices may be connected to the electrical mains supply only by a specialist
company registered within the electrical trade and approved by the energy supplier.
Ø
All locally applicable standards and regulations must be observed during the connection to the electrical mains sup-
ply.
Ø
A protective circuit must be connected properly.
Ø
The electrical safety of this warewasher is guaranteed only if it is connected to a correctly installed protective circuit.
Ø
The wiring diagram must be observed.
Ø
The warewasher may be operated only at the voltages and frequencies specified on the rating plate.
Ø
For machines delivered without a plug, a fixed connection must be installed as an overriding priority.
Ø
The electrical connection must be secured as a separately fused circuit with slow fuses or circuit breakers. The fuse protection de-
pends on the total connected load of the warewasher. The total connected load is specified on the rating plate of the warewasher.
Ø
If a residual current circuit breaker is provided on-site, we recommend installing a Class B all-current sensitive residual current cir-
cuit breaker.
Ø
Determine the cable cross-section of the mains cable using the following table:
Voltage
Frequency [Hz]
380 V, 3N~
400 V / 3N~
415 V / 3N~
200 V / 3~
230 V / 3~
230 V / 1N~
240 V / 1N~
230 V / 1N~ and 240 V / 1N~ don't apply for Australia and New Zealand.
The mains cable must be a H07RN-F type or equivalent.
Operating instructions
On-site fuse protection [A]
50
60
50
60
50
60
50
60
50
60
50
60
50
60
|
12020321/01; 2023-07
16
16
25
32
15
16 / 20
25
32
25
32
25
32
32
25
32
40
50
|
|
|
Commissioning
5
English
Cable cross-section [mm²]
2,5
2,5
4
6
2,5
2,5
4
6
4
6
4
6
6
4
6
10
10
63