Example of Basic settings

5.2
Basic settings should only be seen as setting values to get burner to start.
Once the burner has started and established flame, it is necessary to adjust the
settings so that they are adapted to the installation and the fuel used.
B 30 A2.2
Burner output:
Estimated nozzle output:
(* Calorfic value Fuel oil
This provides the following nozzle according to the nozzle table, (see Technical
data).
154 kW distributed over 2 nozzles:
Nozzle Stage 1:
Nozzle Stage 2:
Pumpetryk:
Setting values for 154 kW according to basic setting diagram, (see Technical
data).
Stage 1
Air
Fuel, Stage 2
Solenoid valve 2
Air
Stage 2
Insert
Stage 2
Selection of output and connection between the different power stages must
be selected and adjusted so that the system achieves good functionality.
154 kW
154 / 11.86*
13.0 kg/h
=
11.86 kWh/kg)
=
2.00 Gph
88 kW
1.50 Gph
66 kW
10.0 bar
=
=
=
=
50
66
82
2.1