Care must be taken by the installer to ensure that no electrical cables
or fuel lines are pinched or otherwise damaged during installation or
service.
Flame tubes, fan wheels and air dampers, for example, may contain
•
sharp edges.
- before fi rst start:
The burner must not be put into operation without proper safety and
•
protection devices.
Permitted ambient temperature during operation -10 to +60 °C. Max.
•
80% relative humidity, no condensation.
The surface temperature of the burner's components may exceed
•
60 °C.
Handle with caution – the burner has moving parts, and there is risk
•
of crushing injuries.
Seal inspections must be performed during installation and servicing
•
to prevent leakage.
fi tting and installation work has been completed and approved.
•
electrical installation has been correctly performed.
•
fl ue gas ducts and combustion air ducts are not blocked.
•
•
all actuators and control and safety devices are in working order and
correctly set.
If the boiler is equipped with an access hatch, this must be equipped
•
with a hatch opening switch connected to the burner's safety system.
When in operation, the burner's noise level can exceed 85 dBA – use
•
hearing protection!
- Operation:
Carry out all stipulated settings, service and inspection work within
•
the set time.
•
If the oil burner control has a solid red light, contact your installer.