Basic Settings; Example Of Basic Settings - Bentone Bentoflex ST 133 KL Installation And Maintenance Instruction

Table of Contents

Advertisement

4. Basic settings

4.1 Example of basic settings

4.1.1
Choice of nozzle
ST 133K 76-26
Burner output
Estimated nozzle output:
Choice of nozzle according to the table (refer to Technical data).
According to the nozzle table, this provides the following nozzle.
Nozzle:
Pump pressure:
ST 133K 76-26 /ST 133KV 76-26
Burner output
Output calculation due to preheater for nozzle choice according to the table
(refer to Technical data).
Estimated nozzle output:
Choice of nozzle according to the table (refer to Technical data).
According to the nozzle table, this results in the following nozzle.
Nozzle:
Pump pressure:
4.1.2 Basic settings
The setting value for 70 kW according to basic settings tables
(Setting values).
Air setting
Insert setting
* Energy value of EO1 fuel oil = 11.86 kWh/kg
70 kW
70 / 11.86*
=
5,90 kg/h
1,50 GPH
11.0 bar
70 kW
70 x 1.06
=
74,2 kW
74,2/11.86 *
=
6,25 kg/h
1,65 GPH
10,5 bar
=
=
11.0
4.0
165 205 29
15
Bentone