Assemble Sprocket base unit
Operation check of Connecting lever
・ Check that when pressing the iron core
with tweezers, etc, in the direction of ① ,
the lever D can be released to move in the
direction of ② , and when pressing the
connecting lever in the directio of ③ , this
does not interfere with the lever D.
・ Attach the screw (#535).
#1522
Sprocket base unit
Connecting lever
Lever D
- A24 ・
-
FAA41051-R.3644.A
#1509
Tweezers
Iron core
#535